Lenz DIGITAL PLUS STANDARD+ Mode D'emploi page 33

Publicité

Les langues disponibles

Les langues disponibles

47
0-7
Function 1 backward
50
Bit
Motor configuration
1-3 (0-2)
Select motor type 0-5, enter as decimal number
4,5 (3,4)
not used
6 (5)
0
EMF switch inactive
1
EMF switch active
7 (6)
0
Control switched on
1
Control switched off
8 (7)
0
High-frequency motor control (approx. 23 kHz)
1
Low-frequency motor control (approx. 19 Hz)
51
Bit
Braking configuration
1-5 (0-4)
not used
6 (5)
1
Stopping with DC independent of the polarity (only if Bit 3 is
deleted in CV29).
7 (6)
Not used
8 (7)
1
Constant braking distance activated
0-255
52
Braking distance with activated constant braking distance
0-255
55
Sets brightness at function output A 255=max
0-255
56
Sets brightness at function output B, 255=max
57
Function mapping:
-
Each bit of the CV stands for a function of the digital system:
Bit 1(0) for function 1, Bit 2(1) for function 2 and so on up to
59,
Bit 8(7) for function 8. If you wish to allocate a function to the
61,
1
2
33
4
4
0 (dec)
0
0
0
0 (dec)
0
0
0
50
255
255
E