List Of Necessary Cables; Preliminary Checks - Key Automation CT1RS Instructions Et Avertissements Pour L'installation Et L'usage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
EN
1
L
N
2
L1
L2
COM
FLASH
+P.OUT
+24V
3
-24V
PH1

2.4 - List of necessary cables

In the typical system, the cables necessary for the connections of
the various devices are indicated in the cable list table.
The cables used must be suitable for the type of installation; for
TECHNICAL SPECIFICATIONS OF ELECTRIC CABLES
Connection
Control unit power supply electrical line
Flashing light
Antenna
Transmitter photocells
Receiver photocells
Sensitive edge
Key selector
* If the power supply cable exceeds 20 m in length, a cable with a larger section (3x2.5 mm2) must be used and a safety earthing must
be installed near the automation

3 - PRELIMINARY CHECKS

Before installing the product, check and verify the following points:
Make sure that the door is suitable for automation;
the weight and size of the door must be within the operating
limits specified for the automation system in which the product is
installed;
check that the door has firm, effective mechanical safety stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the
product to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide
temperature variations or high temperatures), friction may
increase, causing a corresponding rise in the force needed to
operate the system; the starting torque may therefore exceed that
required in normal conditions;
check that when operated by hand the door moves smoothly
18
Rapid fuse 5A (F1)
Safety earth
230Vac power supply phase
230Vac power supply neutral
Motor close terminal
Motor open terminal
Common of motor
Flashing light / 230Vac courtesy light
gate open light / photo devices test
Non-regulated 24Vdc output
Non-regulated 24Vdc output
Photocell input (NC)
STOP
COM
OPEN
Input open (N.O.) / limit switch open (N.C.)
3
CLOSE
input closed (N.O.) / limit switch close (N.C.)
SEQ
COM
Shield
4
FRONT
5 DIP-Switch
6
Trimmer
7
Buttons
8
LED
example, a cable type H03VV-F is recommended for installation
indoors or H05RN-F/H07RN-F if laid outdoors.
cable
1 x cable 3 x 1.5 mm
2
1 x cable 2 x 0.5 mm
2
1 x cable type RG58
1 x cable 2 x 0.5 mm
2
1 x cable 4 x 0.5 mm
2
1 x cable 2 x 0.5 mm
2
1 x cable 4 x 0.5 mm
2
without any areas of greater friction or derailment risk;
check that the door is well balanced and will therefore remain
stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and
differential safety breaker device;
the system power supply line must include a circuit breaker
device with a contact gap allowing complete disconnection in the
conditions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
Stop input (N.C.) / edge 8k2
Common for inputs
SBS button (N.O.)
Common for inputs
Sock
Antenna
DIP-Switch
Increase rotating clockwise
P1 and P2
Three-colour indicator LED
maximum limit permitted
20 m *
20 m
20 m (recommended < 5 m)
20 m
20 m
20 m
20 m

Publicité

Table des Matières
loading

Table des Matières