GE UVW9301 Manuel De L'utilisateur Et Instructions D'installation page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION HEIGHT TABLE
Installation Height with Supplied Duct Covers
Possible Vented
Ceiling
Install Height
Height (ft./in.)
(in.)
7' 6"
24
7' 7"
24-25
7' 8"
24-26
7' 9"
24-27
7' 10"
24-28
7' 11"
24-29
8'
24-30
8' 1"
24-31
8' 2"
24-32
8' 3"
24-33
8' 4"
24-34
8' 5"
24-35
8' 6"
24-36
8' 7"
24-36
8' 8"
24-36
8' 9"
24-36
8' 10"
24-36
8' 11"
24-36
9'
24-36
9' 1"
24-36
9' 2"
24-36
9' 3"
24-36
9' 4"
24-36
9' 5"
24-36
9' 6"
25-36
9' 7"
26-36
9' 8"
27-36
9' 9"
28-36
9' 10"
29-36
9' 11"
30-36
10'
31-36
10' 1"
32-36
10' 2"
33-36
10' 3"
34-36
10' 4"
35-36
10' 5"
36
7/8" min
29-7/16" max
46-7/8"
12" High Ceiling Duct Cover Kit
29-6326
Installation Preparation
Possible Vented
Install Height
Possible
(Recirculation
Recirculation
vented Holes
Install
Hidden) (in.)
Height (in.)
24
24-25
24-26
24-27
24-28
24-29
24-25
24-30
24-26
24-31
24-27
24-32
24-28
24-33
24-29
24-34
24-30
24-35
24-31
24-36
24-32
24-36
24-33
24-36
24-34
24-36
24-35
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
25-36
24-36
26-36
24-36
27-36
24-36
28-36
24-36
29-36
25-36
30-36
26-36
31-36
27-36
32-36
28-36
33-36
29-36
34-36
30-36
35-36
31-36
36
32-36
33-36
34-36
35-36
*Based on a 36" electric range height.
For gas range, start chart at 92" and subtract 2" for the maximum install height for each block.
Upper
Duct Cover
Lower
Duct Cover
Hood Body
(UX12DC93SS or
UX12DC93TS)
Optional High Ceiling Duct Cover
up to 12 ft.
(not included with unit)
Ceiling
Height (ft./in.)
9' 3"
9' 4"
9' 5"
9' 6"
24
9' 7"
9' 8"
9' 9"
9' 10"
9' 11"
10'
10' 1"
10' 2"
10' 3"
10' 4"
10'5"-11'3"
11' 4"
11'5"
11'6"
11'7"
11'8"
11'9"
11'10"
11' 11"
12'
36
46-1/4" max
(UX14DC93SS or
UX14DC93TS)
Optional High Ceiling Duct Cover
up to 14 ft.
(not included with unit)
Vented and
Recirculation
Ceiling
Height (in.)
Height (in.)
24
12'
24-25
12' 1"
24-26
12' 2"
24-27
12' 3"
24-28
12' 4"
24-29
12' 5"
24-30
12' 6"
24-31
12' 7"
24-32
12' 8"
24-33
12' 9"
24-34
12' 10"
24-35
12' 11"
24-36
13'
24-36
13' 1"
24-36
13' 2"
24-36
13' 3"
24-36
13' 4"
24-36
13' 5"
24-36
13' 6"
25-36
13' 7"
26-36
13' 8"
27-36
13' 9"
28-36
13' 10"
29-36
13' 11"
14'
Upper
7/8" min
Duct Cover
46-7/8"
Lower
Duct Cover
Hood Body
14" High Ceiling Duct Cover Kit
Vented and
Recirculation
Install
Height (in.)
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
24-36
25-36
26-36
27-36
28-36
29-36
30-36
31-36
32-36
33-36
34-36
35-36
36
1' = 0.3 m: 1" = 2.5 cm
13

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Uvw9361

Table des Matières