To Learn More...

Operation mode

• It is possible to operate the indoor units individually or simultaneously. The priority of
operation is placed on the fi rst unit that turned on.
• During operation, HEAT and COOL modes cannot activate at the same time for different
indoor units.
• The power indicator blinks to indicate the indoor unit is standing by for different operation
mode.
AUTO : The POWER indicator blinks at the initial stage.
Single • The unit will select an operation mode every 10 minutes depending on the setting
and room temperature.
• The unit will select an operation mode every 3 hours depending on the setting,
Multi
room and outdoor temperature.
HEAT : The POWER indicator blinks at the initial stage. The unit will take some time to
warm up.
• If the HEAT mode system has been locked, and other operation mode is selected,
the indoor unit stops and the POWER indicator blinks.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY
: Operates at low fan speed for a gentle cooling operation.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
HEAT : 20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL: 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air fl ow direction
In COOL/DRY mode:
The horizontal fl ap swings up/down automatically.
Once the temperature is achieved, the horizontal fl ap is fi xed at upper position.
In HEAT mode:
The horizontal fl ap fi xed at the predetermined position.
The vertical fl ap swings left/right when the temperature rises.
In COOL/DRY/HEAT mode:
The horizontal fl ap swings up/down automatically.
In MILD DRY (Not applicable for Multi split system):
When vertical airfl ow direction is set to AUTO, it stops at lower position to avoid cold air
contact. However, you can adjust the fl ap direction manually.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the
last operation mode and airfl ow direction.
• This control is not applicable when TIMER is set.
18
Single Single split system
Multi Multi split system