To Learn More; Operation Mode - Panasonic CS-Z7SKEW Comment Utiliser L'appareil

Masquer les pouces Voir aussi pour CS-Z7SKEW:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14

To learn more...

Operation mode

AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation.
COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
• For system which HEAT mode has been locked, if operation mode other than HEAT is selected, the indoor unit stops
and the POWER indicator blinks.
ECONAVI
The unit will start to initialise
(for approximately 1 minute)
Human activity sensor operation
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
COOL/DRY
HEAT
ECONAVI
Precise control of temperature during low activity to maximise energy saving.
Mode
COOL/DRY
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
COOL/DRY
HEAT
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
10
The human activity sensor
and the sunlight sensor will
start to detect.
Human
Low activity
Set
temperature
Human
Low activity
Set
temperature
Set
temperature
Note
AIR SWING
Normal activity
+1°C
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature to
maximise energy saving without sacrifi cing the comfort.
+1 °C
-1 °C
When manual AIR SWING is selected,
the ECONAVI operations will be
cancelled.
High activity
Absent
-2 °C
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
-1 °C
+2°C
-2 °C

Publicité

Table des Matières
loading

Table des Matières