Risk of crushing the rack
During gate travel, limbs and fingers may be pinched or crushed between the
gear and the rack!
SAFETY INSTRUCTION FOR HAZARD AVOIDANCE
x Do not touch the gear or rack while the gate is moving.
x Ensure that children do not touch the gear wheel or gear rack during the
gate movement.

21.2. Setting the control unit

The electrical connection must be made according to the enclosed control in-
structions "47-21-0" (optionally "47-21-i").
x The 8-pin dip switch of the control unit 47-21-0 is used to activate speci-
al functions of the motor control unit. It is not a coding switch for the
radio.
x The gate requires a mechanical end stop in the end positions "OPEN"
and "CLOSED" so that the gate cannot run out of the guide in case of a
fault.

21.3. Test run with control unit 47-21-0

Push the door manually to the "centre" position and lock the door (using the
emergency release).
Press the pulse button on the motor control board and let the door run by me-
ans of the drive. Check the end positions. You can regulate the end positions by
moving the permanent magnets.
In the first two test runs of the door, the running time and the power require-
ment are automatically saved. The running time determines the soft start of
the door, the power requirement determines the ampere stop.

21.4. Test run with control unit 47-21-i

The motor control unit 47-21-i is used to perform the learning runs in the menu
and to correct the end positions with the + and - buttons. Please refer to the
installation instructions for motor control unit 47-21-i under item "Learning
runs".