• Connect the mains cable plug into a socket. By way of a test, the detector will beep
briefly and the 3 LEDs (fig. 1a - 1c) will flash once.
• The green LED (fig. 1a) will flash for approx. 10 minutes (warm-up phase). If the green LED
lights up continuously, the device is operational.
• Press the test button (fig. 1d) (for up to 5 seconds) until a loud, pulsating alarm signal
can be heard (see Section 5 Test/Maintenance).
• To relay the alarm, use the terminal on the reverse of the detector (fig. 1f). If the alarm
is triggered, 9 V will be output.
The PROTECTOR GD 230 V ∼ is not able to receive alarm signals.
You have the option of connecting the detector to the following devices:
- PROTECTOR switching relay (accessory) (fig. 1g)
- up to 30 PROTECTOR 9 V smoke detectors
- PROTECTOR RF-IO-Module