3.3.6 INITIAL FIRING

When lit for the first few times, the appliance may emit an odor resulting from evaporation of paint and
lubricants used in the manufacturing process. Open a door or window (or both) for ventilation. Anyone with a
respiratory condition may need to leave the room during the initial firings. Burn for a minimum of 4 hours on
high with the fans on low to clear this condition. Do not touch the glass during burn in.
It is normal for the appliance to expand and contract while it heats up or cools down whether this is from a cold start or
a steady-state condition where the fan has come on or off. Under these circumstances it is possible that the
Il est normal que l 'appareil à dilater et se contracter pendant qu'elle se réchauffe ou se refroidit s'il s'agit d'un
démarrage à froid ou d'un état d'équilibre où le ventilateur est venu sous ou hors tension. Dans ces circonstances, il
est possible que l'expansion et la contraction des pièces métalliques peuvent produire des sons
Occasionally, after a cold start, vapor may condense and fog the glass, and the flames may be partially blue.
After a few minutes the moisture will disappear and the flames will become yellow. Visually check the flame
after warm-up. / Parfois, après un démarrage à froid, la vapeur peut se condenser et voiler le verre, et les
flammes peuvent être partiellement bleu. Après quelques minutes, l'humidité disparaît et les flammes
deviendront jaunes. Contrôler visuellement la flamme après l'échauffement.

3.3.7 PILOT FLAME ADJUSTMENT

For proper operation, the pilot and main burner flames must be steady and not lifting off or floating. The top
3/8" – 1/2" (10-13mm) of the
Thermocouple should be
engulfed by the pilot flame.
3.3.8 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
Aeration is factory set but may need adjustment for altitude or movement during shipping. / L'aération est
réglée en usine, mais peut nécessiter un ajustement de l'altitude ou le mouvement pendant le transport.
To adjust the air shutter / Pour ajuster l'obturateur d'air
1/. Turn off the gas / Fermez le gaz
2/. Remove the front outer and inner glass / Retirez les vitres extérieure et intérieure avant
3/. Remove glass or logs from burner / Retirer le verre ou des billes de brûleur
4/. Remove the burner pan / Retirer la casserole du brûleur
5/. Undo the set screw on the air shutter and adjust accordingly then retighten the set screw. / Défaire la
vis de réglage sur le volet d'air et d'ajuster en conséquence, puis resserrez la vis de réglage.
6/. Reassemble the fireplace in reverse order from 4 through 2. / Remonter la cheminée dans l'ordre
inverse de 4 à 2.
7/. Turn on the gas. / Allumez le gaz.
expansion/contraction of the metal parts may produce sounds.
Set Screw
Air tube and Air shutter shown removed
for clarity purposes only.