RIB SUPER 3600 Manuel page 37

Masquer les pouces Voir aussi pour SUPER 3600:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EVENT
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
DIP 2 ON (full stroke programming)
DIP 2 ON > DIP 1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
EVENT
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for full opening
DIP 1 ON > DIP 3 ON - transmitter code programming for pedestrian opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 s tone with 2 s pause
BUZZER STATUS
1 Tone
1 Tone
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
1 Tone
2 Tones
2 Tones every 5 s for 1 minute
(It is renewed by giving a command)
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
6 Tones every 5 s
(It is renewed by giving a command)
Continuous tone for 10 s with 2-s pause.
Not active when DIP 2 in OFF
37
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FLASHER STATUS
OFF
OFF
OFF
OFF
OFF
OFF
Flashes for 1 minute
OFF
OFF
OFF
OFF
OFF
OFF
OFF
DL1 LED STATUS
Flashes ON/OFF 250 ms
Flashes ON/OFF 500 ms
Flashes ON/OFF 500 ms
On steady
DL12 LED STATUS
Flashes red/green
Flashes red for 10 s
Flashes green for 10 s
Flashes orange for 10 s
Turns green once
Turns red once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns OFF
Led DL7-8 turns OFF
Led DL9-10 turns OFF
Led DL1 flashes ON/OFF 250 ms
No led combined
No led combined
Led DL12 is steady on green.
No leds matched
Blue led flashes once every 5 s
No leds matched
G
B