VOLTCRAFT VC-86 Notice D'emploi page 35

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Current measurement (only VC-86)
Currents of up to 400mA can be measured in the current measure-
ment area. The current measurement area is secured and thus pro-
tected against overloading.
Proceed as follows to measure dc currents:
- Turn range selction switch (10) to position "A"
- The polarity of the measuring figure concerned will be displayed
in the display together with the current measuring value in the dis-
play (6).
Proceed as follows to insert or measure alternating currents:
- Press button "S" (5) in the current measurement area, to change
to the AC area; if you press it again, you will switch back to the
DC area.
- The polarity of the measuring figure concerned will be displayed
in the display together with the current measuring value in the dis-
play (6).
Never operate the measurement device when it is
open.
Max-Hold Function (only VC-82)
The VC-82 has a MAX-Hold Function. If you press during a measu-
ring the MAX button (7), the item shows automatically the highest
measuring value on the LCD (6). To deactivate this funktion, press
MAX button (7) again.
35

Publicité

Table des Matières
loading

Table des Matières