Télécharger Imprimer la page

Lenz Digital plus SILVER+PluX12 Mode D'emploi page 29

Publicité

Les langues disponibles

Les langues disponibles

The length of the covered braking distance is set in CV52. The braking distance differs
depending on the value set in this CV.
If you want to use the constant braking distance with both speed step 0 and ABC, set both bits
in CV51.
While the shunting speed is switched off (default setting F3), the constant braking distance is
disabled and the delay from CV4 becomes effective.
The constant braking distance is also disabled if the delays set in the decoder are disabled by
means of the corresponding function.
The two latter features can also be used sensibly if you wish to interrupt a current braking process
prematurely.
The constant braking distance does not work if the layout is operated in analogue DC mode.
4.6 Shunting speed
The shunting speed halves the speed. This facilitates particularly sensitive control of the shunting
process. Use function 3 (ex-works setting, can be altered in CV59) to enable and disable the
shunting speed. If the shunting speed is enabled, the constant braking distance is disabled. The
shunting speed is enabled as long as the function is active.
4.7 ABC = simple signal stop and slow approach
You can carry out a particularly simple signal stop using the ABC braking module. Depending on the
signal position, this module creates an asymmetric track voltage in the braking section in front of the
signal. The decoder reacts to this. Combined with the constant braking distance, precise on-the-
spot stopping in front of red signals is not a problem. Of course, passage in the opposite direction is
also possible. The signal indication "slow approach/caution" does not pose a problem; the
respective maximum-speed can be set in CV53.
29
E

Publicité

loading

Ce manuel est également adapté pour:

10312-01