Preparations

A water connection 23 mm long with G ½" internal thread and a thread length of at least 15 mm must
be available for installation (see Fig. 1).
A correctly installed and earthed socket outlet must also be available.
Mark and drill holes accordingly (see Fig. 2) and insert 6 mm dowels.
Use a spirit level to ensure they are centred and horizontal!
Montagewand
Mounting wall
G ½"
G1/2"

Montage

1. Remove cover (1). For this purpose, unhook the two de-
tents (2), i.e. press them gently away from the appliance
with a small screwdriver or your hand and lift off the
cover.
2. With two fork wrenches size 30 and size 27 unscrew the
connection between the union nut ¾" (4) and the water
connection (5).
3. Using a size 27 fork wrench, screw in the water connec-
tion (5) with hemp or PTFE tape. Check the distance of
40 mm (Fig. 4).
15
23
Fig. 1
150
Water connection ½"
Wasseranschluss 1/2"
5
20
256
Fig. 2
Montagewand
Mounting wall
40
Fig. 3