Lubrication - Campbell Hausfeld CE4104 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions (CONTINUED)

Lubrication

This unit contains no oil. Before
operating compressor, fill to the center
of the sight gauge (see Figure 6).
Using any other type of oil may
shorten pump life and damage valves.
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Part number ST126700AV.
10W30 synthetic oil such as Mobil 1
Oil Capacity
Approximately 40 oz.
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 6).
through the breather cap opening as this may cause oil to leak
and spray out during operation.
NOTE: Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.
OPERATING INSTRUCTIONS
IMPORTANT: Check motor rotation before operating the
compressor.
All lubricated compressor pumps discharge some
condensed water and oil with the compressed air. Install
appropriate water/oil removal equipment and controls as
necessary for the intended application.
Failure to install appropriate
water/oil removal equipment may result
in damage to machinery or workpiece.
Guarding
The belt guard provided must be
installed before operating the unit.
All moving parts must be guarded. All electrical covers must
be installed before turning on the power.
®
.
Do NOT fill the pump
Figure 6 - Lubrication
10
Oil Fill Plug
Oil Drain Plug
breather)
Full
Low
Sight Gauge
(behind

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tq3104

Table des Matières