INSTALLATION INSTRUCTIONS

Disconnect, tag and lock out power source then release all pressure from the system before
attempting to install, service, relocate or perform any maintenance.
Do not lift or move unit without appropriately rated equipment. Be sure the unit is securely
attached to lifting device used. Do not lift unit by holding onto tubes or coolers. Do not use unit
to lift other attached equipment.
Never use the wood shipping skids for mounting the compressor.
Picking the Location
Install and operate unit at least 18 inches from any obstructions
in a clean, well ventilated area. The surrounding air temperature
should not exceed 100° F. This will ensure an unobstructed flow of
air to cool compressor and allow adequate space for maintenance.
Do not locate the compressor air inlet near steam,
paint spray, sandblast areas or any other source
of contamination.
NOTE: If compressor operates in a hot, moist environment, supply
compressor pump with clean, dry outside air. Supply air should be
piped in from external sources.
Tank Mounting
The tank should be bolted into a flat, even, concrete floor or on a
separate concrete foundation. Vibration isolators should be used
between the tank leg and the floor. Part number MP345700AJ
isolator pads are recommended for units.
When using isolator pads, do not draw bolts tight. Allow the pads
to absorb vibrations. When isolators are used, a flexible hose or
coupling should be installed between the tank and service piping.
Failure to properly install the tank can lead
to cracks at the welded joints and possible
bursting.
Piping
Never use plastic (PVC) pipe for compressed air.
Serious injury or death could result.
Any tube, pipe or hose connected to the unit must be able to
withstand the temperature generated and retain the pressure. All
pressurized components of the air system must have a pressure
rating of 200 psi or higher. Incorrect selection and installation of
any tube, pipe or hose could result in bursting and injury. Connect
piping system to tank using the same size fitting as the discharge port.
CFM
10
20
40
60
100
Minimum Pipe Size For Compressed Air Line
LENGTH OF PIPING SYSTEM
25 FEET
50 FEET
1/2 inch
1/2 inch
3/4 inch
3/4 inch
3/4 inch
1 inch
3/4 inch
1 inch
1 inch
1 inch
7
Figure 2 - Location
Figure 3 - Isolator Pad
100 FEET
250 FEET
3/4 inch
3/4 inch
3/4 inch
1 inch
1 inch
1 inch
1 inch
1 inch
1 inch
1-1/4 inch