Portable Air Compressors
Operation (Cont.)
2. Be sure this gauge reads ZERO before
changing air tools or disconnecting hose
from outlet.
TANK PRESSURE GAUGE
Gauge shows pressure in air receiver
indicating compressor is building pressure
properly.
Maintenance
Release all
WARNING
!
pressure and
disconnect power before making any
repair.
1. Check compressor for any visible
problems, especially check air filter to be
sure it is clean.
2. Pull ring on safety valve and allow it to
snap back to normal position.
Figure 7
Safety valve must
WARNING
!
be replaced if it
cannot be actuated or it leaks air after ring
is released.

Troubleshooting Chart

Symptom
Compressor will not run
Motor hums but cannot
run or runs slowly
www.chpower.com
3. Daily with compressor shut off: Drain
moisture from tanks by opening drain
cocks underneath end of tanks.
Drain
Cock
Figure 8
4. Turn power OFF and clean dust and dirt
from motor, tank, air lines and pump
cooling fins.
NOTE: This unit has no air filter to
maintain.
IMPORTANT: Unit should be located as
far from spraying area as hose will allow.

LUBRICATION

This is a compressor that requires no
additional lubrication.
THERMAL OVERLOAD PROTECTOR
CAUTION
!
automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.
Possible Cause(s)
1. Loss of power or overheating
2. No electrical power
3. Blown fuse
4. Breaker open
5. Thermal overload open
6. Pressure switch bad
7. Tank is full of air
1. Low voltage
2. Wrong gauge wire or length of
extension cord
3. Shorted or open motor winding
4. Defective check valve or unloader
If thermal overload protector shuts motor
OFF frequently look for the following
causes.
1. Low voltage.
2. Wrong gauge wire or length of
3. Lack of proper ventilation.
down before start-up is possible. The
motor will automatically restart without
warning if left plugged into electrical
outlet, if the motor is turned on.
STORAGE
1. When not in use, hose and compressor
2. Tank should be drained of moisture.
3. Hose should be disconnected and hung
This compressor is
equipped with an
Corrective Action
1. Check for proper use of extension cord (see
EXTENSION CORDS, page 3)
2. Plugged in? Check fuse/breaker or motor overload
3. Replace blown fuse
4. Reset, determining why problem happened
5. Motor will restart when cool
6. Replace
7. Take compressor to authorized Campbell Hausfeld
service center. Compressor will turn on when tank
pressure drops to cut in pressure
1. Check with voltmeter
2. Check gauge chart, under Operation for proper
gauge wire and cord length
3. Take compressor to authorized Campbell Hausfeld
service center
4. Take compressor to authorized Campbell Hausfeld
service center
4
extension cord.
The motor must be
CAUTION
!
allowed to cool
should be stored in a cool dry place.
open ends down to allow any moisture
to drain.