Campbell Hausfeld FP Serie Instructions D'utilisation page 3

Masquer les pouces Voir aussi pour FP Serie:
Table des Matières

Publicité

Installation
(Cont.)
Do not use an adapter
DANGER
!
with this product!
Operation
FOR TROUBLE-FREE OPERATION
1. Read instructions: Carefully read
through this owner's manual BEFORE
OPERATING the new air compressor.
It contains information about
operation and maintenance of unit.
2. Break in: Allow new compressor to
run for at least 15 minutes without
compressing air, to properly seat
working parts. See Break-In
instructions.
3. Drain tank daily: Open drain cock and
drain moisture from tank. Be sure to
close cock tightly before operating
compressor. This helps prevent tank
corrosion and keeps oil and moisture
out of air used.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will
form into droplets as it comes
from an air compressor pump.
When humidity is high or when a
compressor is in continuous use
for an extended period of time,
this moisture will collect in the
tank. When using a paint spray or
sandblast gun, this water will be
carried from the tank through the
hose, and out of the gun as
droplets mixed with the spray
material.
IMPORTANT: This condensation
will cause water spots in a paint
job, especially when spraying
other than water based paints. If
sandblasting, it will cause the
sand to cake and clog the gun,
rendering it ineffective.
A filter in the air line, located as
near to the gun as possible, will
help eliminate this moisture.
Length of Cord (ft)
Gauge of Cord
BREAK-IN
CAUTION
!
to open end of hose until start-up has
been completed and unit checks OK.
1. Turn regulator knob fully clockwise.
Close
Figure 2
2. Turn switch to OFF position, and plug
in power cord.
Off
position
Figure 3
3. Turn switch to ON position and run
unit for 30 minutes to break in pump
parts.
4. Turn regulator knob fully
counterclockwise. Compressor will
build to maximum preset pressure and
shut off.
5. Turn regulator knob clockwise to
cause air to bleed off. Compressor will
restart at present pressure.
6. Turn regulator knob counterclockwise
to shut off air and turn switch to OFF
position.
7. Attach air chuck or other tool to open
end of hose. Turn regulator fully ON.
Apply a soap and water solution
around hose fittings and check for
signs of leaks (bubbles forming). If
there is a leak, tighten connections
and check again. When there are no
leaks, compressor is ready for
operation.
Extension cords for 120V/5 Amp Unit
25
50
100
18
18
14
Home Workshop (FP) Models
Do not attach air
chuck or other tool
Open
On
position
150
200
250
12
12
10
3
Figure 4
ASME SAFETY VALVE
1. This valve automatically releases air if air
receiver pressure exceeds preset
maximum.
Do not attempt to
DANGER
!
tamper with this
valve!
2. This valve should be checked
occasionally by pulling the ring by hand.
If air leaks after ring has been released,
or valve is stuck and cannot be actuated
by ring, it MUST be replaced.
Figure 5
REGULATOR KNOB
1. This knob controls air pressure to an air
operated tool, or paint spray gun.
2. Turning knob clockwise increases air
pressure at outlet.
3. Turning counterclockwise will lower air
pressure at outlet.
4. Fully counterclockwise will shut off flow
of air completely.
Close
Figure 6
REGULATED OUTLET GAUGE
1. This gauge shows at-a-glance, air
pressure at outlet. Air pressure is
measured in pounds per square inch
(psi).
300
400
10
8
www.chpower.com
Open
500
8

Publicité

Table des Matières
loading