Input Data for Potentiometer (Ratio)
Input
Connection
Supply current
Line monitoring
Accuracy
Temperature coeffi cient at
input
Input Data for Shunt (Voltage)
Input
Input resistance
Accuracy
Line monitoring
Temperature coeffi cient at
input
Overload capacity
200 Ω ... 50 kΩ
3- or 4-wire (4-wire via IRDA only)
0 ... 5 mA
Open circuits
< (0.2% full scale + 0.05% meas.val.)
for spans > 5 %
50 ppm/K of adjusted end value
(average TC in permitted operating
temp range, reference temp 23 °C)
-1000 ... 1000 mV unipolar/bipolar
> 10 MΩ
± (200 μV + 0.05% meas.val.)
for spans > 50 mV
Open circuits
50 ppm/K of adjusted end value
(average TC in permitted operating
temp range, reference temp 23 °C)
5 V across all inputs