Connection for Voltage Measurement

11
1
2
=
3
4
Voltage

Connection for Strain Gauge Bridges (DMS)

13
V
Diff
Strain gauge
Terminal 1: Bridge supply voltage (+)
Terminal 4: Bridge supply voltage (-)
Terminal 2: Measured signal (+)
Terminal 3: Measured signal (-)
You can confi gure all functions of the transmitter using the Paraly SW 111 software.
Wirings with a shaded number can only be adjusted via IrDA.
12
Shunt
1
2
3
4
Wiring Possibilities
1
2
3
4
14
=
Strain gauge
External supply (1 ... 3 V)
Terminal 1: Sense line (+)
Terminal 4: Sense line (-)
Terminal 2: Measured signal (+)
Terminal 3: Measured signal (-)
1
V
Diff
2
3
4