Technical Data; Technische Daten; Deutsch - Milwaukee PD2E 22 RS Mode D'emploi

Table des Matières

Publicité

TECHNICAL DATA

Rated input .................................................................................................
Output .........................................................................................................
No-load speed, 1st gear .............................................................................
No-load speed, 2nd gear ............................................................................
Speed under load max., 1st gear ...............................................................
Speed under load max., 2nd gear ..............................................................
Rate of percussion under load max ............................................................
Static jamming moment*, 1st gear/2nd gear...............................................
Drilling capacity in concrete ........................................................................
Drilling capacity in brick and tile .................................................................
Drilling capacity in steel ..............................................................................
Drilling capacity in wood .............................................................................
Drill opening range .....................................................................................
Drive shank.................................................................................................
Chuck neck diameter ..................................................................................
Weight according EPTA-Procedure 01/2003 ..............................................
Typical weighted acceleration in the hand-arm area ..................................
Typical A-weighted sound levels:
Sound pressure level (K = 3 dB(A)) ..........................................................
Sound power level (K = 3 dB(A)) ..............................................................
Measured values determined according to EN 60 745.
The data stated above apply for models with 230 - 240 V. In case of deviating mains voltage, the data stated on the rating plate are applicable. *
Measured according to Milwaukee norm N 877318
SAFETY INSTRUCTIONS
WARNING! Read all safety warnings and all instructions, including those
given in the accompanying brochure. Failure to follow the warnings and
instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
Wear ear protectors. Exposure to noise can cause hearing loss.
Use auxiliary handles supplied with the tool. Loss of control can cause personal
injury.Appliances used at many different locations including open air must be
connected via a current surge preventing switch.
Hold power tool by insulated gripping surfaces, when performing an operation
where the cutting accessory may contact hidden wiring or its own cord. Contact
with a „live" wire will also make exposed metal parts of the power tool „live" and
shock the operator.
Appliances used at many different locations including open air must be connected via
a current surge preventing switch.
Always wear goggles when using the machine. It is recommended to wear gloves,
sturdy non slipping shoes and apron.
Sawdust and splinters must not be removed while the machine is running.
Always disconnect the plug from the socket before carrying out any work on the
machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always lead the cable
away behind you.
When working with large drill diameters, the auxiliary handle must be fastened in a
right angle with the main handle (see illustrations, section „Twisting the handle").
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or floor, take care to avoid electric cables and gas or
waterpipes.
SPECIFIED CONDITIONS OF USE
The electronic drill/screwdriver can be universally used for drilling, percussion drilling,
screwdriving and cutting screw threads.
Do not use this product in any other way as stated for normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the system voltage indicated on
the rating plate. It is also possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in conformity with the
following standards or standardized documents:
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
20
ENGLISH
PD2E 22 RS
PD2E 24 RS
PD2E 24 RST
............850 W ....................... 1010 W .........................1200 W
............425 W ......................... 505 W ...........................505 W
.......0-1400 min
-1
................ 0-1450 min
-1
..................0-1450 min
.......0-3300 min
................ 0-3400 min
..................0-3400 min
-1
-1
............800 min
-1
..................... 980 min
-1
..................... 1150 min
..........2000 min
................... 2400 min
.....................2700 min
-1
-1
........32000 min
-1
................. 37600 min
-1
...................43200 min
.........51/28 Nm .................... 54/30 Nm ......................56/32 Nm
..............20 mm ........................ 20 mm ...........................22 mm
..............22 mm ........................ 24 mm ...........................24 mm
..............13 mm ........................ 16 mm ...........................16 mm
..............40 mm ........................ 40 mm ...........................45 mm
...........1-13 mm ..................... 1-13 mm ........................1-13 mm
......1/2"x20 ...................... 1/2"x20 .........................1/2"x20
..............43 mm ........................ 43 mm ...........................43 mm
.............2,9 kg .......................... 3,1 kg ............................3,1 kg
................7 m/s
......................... 7 m/s
............................7 m/s
2
2
............101 dB (A) .................. 101 dB (A).....................101 dB (A)
............ 112 dB (A) ...................112 dB (A)..................... 112 dB (A)
Winnenden, 2012-09-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical file
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
If the machine is mainly used for percussion drilling, regularly remove collected dust
from the chuck. To remove the dust hold the machine with the chuck facing down
vertically, and completely open and close the chuck. The collected dust will fall from
the chuck. It is recommended to regularly use cleaner for the clamping jaws and the
clamping jaw borings.
Use only Milwaukee accessories and Milwaukee spare parts. Should components
need to be replaced which have not been described, please contact one of our
Milwaukee service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state the ten-digit No.
as well as the machine type printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Always disconnect the plug from the socket before carrying out
any work on the machine.
Accessory - Not included in standard equipment, available as an
accessory.
Do not dispose of electric tools together with household waste
material! In observance of European Directive 2002/96/EC on
waste electrical and electronic equipment and its implementation
in accordance with national law, electric tools that have reached
the end of their life must be collected separately and returned to
an environmentally compatible recycling facility.
Class II construction, tool in which protection against electric
shock does not rely on basic insulation only, but in which
additional safety precautions, such as double insulation or
reinforced insulation, are provided.

TECHNISCHE DATEN

Nennaufnahmeleistung ..........................................................................................
Abgabeleistung .......................................................................................................
-1
Leerlaufdrehzahl im 1. Gang ..................................................................................
Leerlaufdrehzahl im 2. Gang ..................................................................................
-1
-1
Lastdrehzahl max. im 1. Gang ...............................................................................
Lastdrehzahl max. im 2. Gang ...............................................................................
-1
-1
Lastschlagzahl max. ...............................................................................................
Statisches Blockiermoment*, 1/2. Gang ................................................................
Bohr-ø in Beton .......................................................................................................
Bohr-ø in Ziegel und Kalksandstein .......................................................................
Bohr-ø in Stahl ........................................................................................................
Bohr-ø in Holz .........................................................................................................
Bohrfutterspannbereich ..........................................................................................
Bohrspindel ..............................................................................................................
Spannhals-ø ............................................................................................................
Gewicht nach EPTA-Prozedur 01/2003 ................................................................
Typisch bewertete Beschleunigung im Hand-Arm-Bereich ..................................
2
Typische A-bewertete Schallpegel:
Schalldruckpegel (K = 3 dB(A)) ............................................................................
Schalleistungspegel (K = 3 dB(A)) .......................................................................
Messwerte ermittelt entsprechend EN 60 745.
Die angegebenen Daten gelten für eine Ausführung mit 230-240 V. Bei Abweichung der Netzspannung sind die auf dem
Leistungsschild aufgeführten Daten gültig. * Gemessen nach Milwaukee Norm N 877318
SPEZIELLE SICHERHEITSHINWEISE
WARNUNG! Lesen Sie alle Sicherheitshinweise und Anweisungen, auch die in
der beiliegenden Broschüre.Versäumnisse bei der Einhaltung der Sicherheitshinweise
und Anweisungen können elektrischen Schlag, Brand und/oder schwere Verletzungen
verursachen.
Bewahren Sie alle Sicherheitshinweise und Anweisungen für die Zukunft auf.
Tragen Sie Gehörschutz. Die Einwirkung von Lärm kann Gehörverlust bewirken.
Benutzen Sie die mit dem Gerät gelieferten Zusatzhandgriffe. Der Verlust der Kontrolle
kann zu Verletzungen führen.
Halten Sie das Gerät an den isolierten Griffflächen, wenn Sie Arbeiten ausführen, bei
denen das Einsatzwerkzeug verborgene Stromleitungen oder das eigene Kabel
treffen kann. Der Kontakt mit einer spannungsführenden Leitung setzt auch die
metallenen Geräteteile unter Spannung und führt zu einem elektrischen Schlag.
Steckdosen in Außenbereichen müssen mit Fehlerstrom-Schutzschaltern ausgerüstet sein.
Das verlangt die Installationsvorschrift für Ihre Elektroanlage. Bitte beachten Sie das bei der
Verwendung unseres Gerätes.
Beim Arbeiten mit der Maschine stets Schutzbrille tragen. Schutzhandschuhe, festes und
rutschsicheres Schuhwerk und Schürze werden empfohlen.
Späne oder Splitter dürfen bei laufender Maschine nicht entfernt werden.
Vor allen Arbeiten an der Maschine Stecker aus der Steckdose ziehen.
Maschine nur ausgeschaltet an die Steckdose anschließen.
Anschlußkabel stets vom Wirkungsbereich der Maschine fernhalten. Kabel immer nach
hinten von der Maschine wegführen.
Bei großen Bohrdurchmessern muss der Zusatzhandgriff rechtwinklig zum Haupthandgriff
befestigt werden (siehe auch im Bildteil, Abschnitt "Handgriff verdrehen").
Bei Arbeiten mit Diamantbohrkronen Schlagwerk ausschalten.
Beim Arbeiten in Wand, Decke oder Fußboden auf elektrische Kabel, Gas- und
Wasserleitungen achten.
BESTIMMUNGSGEMÄßE VERWENDUNG
Der Elektronik-Schlagbohrer/Schrauber ist universell einsetzbar zum Bohren,
Schlagbohren, Schrauben und Gewindeschneiden.
Dieses Gerät darf nur wie angegeben bestimmungsgemäß verwendet werden.
NETZANSCHLUSS
Nur an Einphasen-Wechselstrom und nur an die auf dem Leistungsschild angegebene
Netzspannung anschließen. Anschluss ist auch an Steckdosen ohne Schutzkontakt
möglich, da ein Aufbau der Schutzklasse II vorliegt.
CE-KONFORMITÄTSERKLÄRUNG
Wir erklären in alleiniger Verantwortung, dass dieses Produkt mit den folgenden Normen
oder normativen Dokumenten übereinstimmt:
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
gemäß den Bestimmungen der Richtlinien
2011/65/EU (RoHs)
2006/42/EG
2004/108/EG
Winnenden, 2012-09-12
PD2E 22 RS
PD2E 24 RS
PD2E 24 RST
............850 W ....................... 1010 W .........................1200 W
............425 W ......................... 505 W ...........................505 W
.......0-1400 min
-1
................ 0-1450 min
-1
..................0-1450 min
.......0-3300 min
................ 0-3400 min
..................0-3400 min
-1
-1
............800 min
-1
..................... 980 min
-1
..................... 1150 min
..........2000 min
................... 2400 min
.....................2700 min
-1
-1
........32000 min
-1
................. 37600 min
-1
...................43200 min
.........51/28 Nm .................... 54/30 Nm ......................56/32 Nm
..............20 mm ........................ 20 mm ...........................22 mm
..............22 mm ........................ 24 mm ...........................24 mm
..............13 mm ........................ 16 mm ...........................16 mm
..............40 mm ........................ 40 mm ...........................45 mm
...........1-13 mm ..................... 1-13 mm ........................1-13 mm
......1/2"x20 ...................... 1/2"x20 .........................1/2"x20
..............43 mm ........................ 43 mm ...........................43 mm
.............2,9 kg .......................... 3,1 kg ............................3,1 kg
................7 m/s
......................... 7 m/s
............................7 m/s
2
2
............101 dB (A) .................. 101 dB (A).....................101 dB (A)
............ 112 dB (A) ...................112 dB (A)..................... 112 dB (A)
Rainer Kumpf
Director Product Development
Bevollmächtigt die technischen Unterlagen
zusammenzustellen
WARTUNG
Stets die Lüftungsschlitze der Maschine sauber halten.
Bei häufigem Schlagbohrbetrieb sollte das Bohrfutter regelmäßig von Staub befreit werden.
Hierzu die Maschine mit dem Bohrfutter senkrecht nach unten halten und das Bohrfutter
über den gesamten Spannbereich öffnen und schließen. Der angesammelte Staub fällt so
aus dem Bohrfutter. Die regelmäßige Verwendung von Reinigungsspray an den
Spannbacken und Spannbackenbohrungen wird empfohlen.
Nur Milwaukee Zubehör und Milwaukee Ersatzteile verwenden. Bauteile, deren Austausch
nicht beschrieben wurde, bei einer Milwaukee Kundendienststelle auswechseln lassen
(Broschüre Garantie/Kundendienstadressen beachten).
Bei Bedarf kann eine Explosionszeichnung des Gerätes unter Angabe der Maschinen Type
und der zehnstelligen Nummer auf dem Leistungsschild bei Ihrer Kundendienststelle oder
direkt bei Milwaukee Electric Tool, Max-Eyth-Straße 10, D-71364 Winnenden, Germany
angefordert werden.
SYMBOLE
Bitte lesen Sie die Gebrauchsanweisung vor
Inbetriebnahme sorgfältig durch.
Vor allen Arbeiten an der Maschine Stecker aus der Steckdose ziehen.
Zubehör - Im Lieferumfang nicht enthalten, empfohlene Ergänzung
aus dem Zubehörprogramm.
Werfen Sie Elektrowerkzeuge nicht in den Hausmüll! Gemäss
Europäischer Richtlinie 2002/96/EG über Elektro- und Elektronik-
Altgeräte und Umsetzung in nationales Recht müssen verbrauchte
Elektrowerkzeuge getrennt gesammelt und einer umweltgerechten
Wiederverwertung zugeführt werden.
Schutzklasse II, Elektrowerkzeug, bei dem der Schutz gegen
elektrischen Schlag nicht nur von der Basisisolierung abhängt,
sondern in dem zusätzliche Schutzmaßnahmen, wie doppelte
Isolierung oder verstärkte Isolierung, angewendet werden.

DEUTSCH

-1
-1
-1
-1
-1
2
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pd2e 24 rsPd2e 24 rst

Table des Matières