22
WIRING TO AN EXTERNAL STANDARD POTENTIOMETER /
COLLEGAMENTO CON POTENZIOMETRO ESTERNO STANDARD
PCB/SCHEDA
1
2 POLES SWITCH (DPST)
POTENTIOMETER
2
(FROM 5 KOHM TO 10 KOHM)
3
ON/OFF SWITCH (SPST)
4
DRY CONTACT FOR ALARM SIGNALLING (250VAC, max current 3A)
23
WIRING TO AN EXTERNAL LOW/HIGH SPEED SWITCH /
COLLEGAMENTO A INTERRUTTORE ESTERNO PER MASSIMA E MINIMA VELOCITÀ
PCB/SCHEDA
1
2 POLES SWITCH (DPST)
2
LOW/HIGH SPEED SWITCH (SPST)
3
DRY CONTACT FOR ALARM SIGNALLING
(250VAC, max current 3A)
LINEO 315 QUIET ES
4
LINEO 315 QUIET ES
2
3
Notes/note:
Don't remove wires connected between contacts "N"
and "L" of PCB and contacts "3" and "4" of terminal
block on cover.
Non rimuovere i fili tra "N" e "L" sul PCB e "3"
e "4" sul coperchio.
COVER/COPERCHIO
2
3
PCB Control Port Description
---------------------------------------
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm
Notes/note:
Don't remove wires connected between contacts "N"
and "L" of PCB and contacts "3" and "4" of terminal
block on cover.
Non rimuovere i fili tra "N" e "L" sul PCB e "3"
e "4" sul coperchio.
MAX
MIN
PCB Control Port Description
---------------------------------------
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm