TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
MOTOR CAPACITOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
NOISE LEVELS
(3)
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(2) Pressure at test point 5)(A)p.8, with zero pressure in the combustion chambre.
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.

ACCESSORIES

(optional):
• RADIO DISTURBANCE PROTECTION KIT Code 3010386
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing to the presence of an
INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres, a protection kit is available as an interface between
the control box and the burner.
POTENTIOMETER KIT Code 3010109
SIGNAL CONVERTER KIT Code 3010390
KIT FOR LPG OPERATION: The kit allows the RX 350-500S/P burners to operate on LPG.
BURNER
OUTPUT kW
Code
OUTPUT POWER REGULATOR KIT: Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates between
the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components should be
ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
- 100...+ 500°C
Pressure
KIT INTERFACE ADAPTER RMG TO PC Code 3002719
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 16.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
kW
MAX.
Mcal/h
kW
MIN.
Mcal/h
kWh/Sm
Mcal/Sm
kg/Sm
Sm
mbar
°C max
rpm
μF / V
V1 - V2
I1 - I2
W max
dBA
RX 350S/P
RX 500S/P
55 ÷ 390
84 ÷ 510
3010391
3010392
Range
Type
PT 100
0...2.5 bar
Output probe
0...16 bar
4...20 mA
RX 350S/P
851 T2
390
335
55
47
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
9.45
3
8.2
3
0.68
3
4.13
/h
11.5
Boilers: water, steam, diathermic oil
°C
0 - 40
60
V
230 ~ +/- 10%
Hz
50 - single-phase
2800
W
300
V
220 - 240
A
2.5
12.5/450
230 V - 2 x 5 kV
1.45 A - 50 Hz - 30 mA
600
IP 44
68
PROBE
Code
3010110
3010213
3010214
5
RX 500S/P
852 T2
510
439
130
112
G25
G20
8.13
9.45
7.0
8.2
0,75
0.68
48
54
16.9
14.7
230 - 400 with neutral ~ +/- 10%
50 - three-phase
2800
650
220/240 - 380/415
3 - 1.7
970
POWER REGULATOR
Type
RWF40
GB
G25
8.13
7.0
0.75
62,7
19
72
Code
3010212

Publicité