22

6.2 Error rectification

App screen
BWT
14ROC COFFEE
leakage
BWT
14ROC COFFEE
pump
cooling
BWT
14ROC COFFEE
no
water
BWT
14ROC COFFEE
009
18
uS
CONDUCTIVITY
H
0 TEMP
2
7.8
186
bar
OUTLET PRESS
DAYS
fault
0001
liter
hours
INLET WATER
PUMP ON
09852
090
liter
liter/hour
OUTLET WATER
OUTLET FLOW
info
back
Flashing LEDs
Error
Water leak in-
side the device
Inlet valve clos-
es automati-
cally.
Status LED turns
red and a warn-
ing signal sounds
Pump motor no
longer working
Status LED flashes
red once evenly
Pump motor no
longer working
The status LED
repeatedly flash-
es twice
The app shows
"fault" for inlet
water.
The device re-
mains in oper-
ation.
The status LED
repeatedly flash-
es three times
Cause
Remedy
Leak or condensa-
Disconnect device
tion inside the de-
from electricity and
vice
water supply
Check pump and
pipes, dry leak sensor
Motor overheat-
The device will re-
ing protection trig-
start automatically
gered
when the motor has
cooled down.
If this error appears
after initial installation
and does not disap-
pear, please check
the electricity supply
to the booster pump.
No or insufficient
Check pre-filter for
raw water input
blockage and replace
if necessary
Check check valves,
open if necessary,
and check flow pres-
sure
4 bar)
Inlet water pres-
Install pressure boost-
sure too low
er if necessary
The inlet water
Permeate is still pro-
meter is blocked
duced but the inlet
or has no power
water volume is not
supply.
recorded.
Check power supply.
Replace inlet water
kit if necessary!
(RO working range: 1 to