RB 170 comfort unit
A
RB 170 ventilation unit
A1
Electronic slide-in module
A2
Control circuit board
A3
Frost protection heating register
B
RB-D1-ZF4 room air control
B1
RB-ZF4 room air control
W1
230 V AC connection cable
W2
Shielded control cable provided by
customer, e.g. LiYCY 2 x 0.75 mm²
for RB-D1-ZF4 room air control
Instead of B1 (RB-ZF4) room air
control, B (RB-D1-ZF4) room air
control can be connected.
W2´
Control cable (provided by custo-
mer) for RB-ZF4 room air control
Outer diameter of control cable
3.2...6.5 mm, e.g. LIYY 6x0.34 mm²
S1
Unit switch
GW1
Gateway frost protection heating
register
M1
Supply air fan
M2
Exhaust fan
S
Door contact switch: Activated
by front plate
T-min
Frost protection temperature sensor
Supply air
Z1 (blue) Potentiometer adjuster
Ventilation level 1
Z2 (blue) Potentiometer adjuster
Ventilation level 2
Z3 (blue) Potentiometer adjuster
Ventilation level 3
Exhaust air
A1 (red) Potentiometer adjuster
Ventilation level 1
A2 (red) Potentiometer adjuster
Ventilation level 2
A3 (red) Potentiometer adjuster
Ventilation level 3
12. Appendix ‒ Wiring diagram for RB 170 comfort unit │ uk
Jumper settings (Chapter 6.7.4)
J 1-3
Unit type, 000 = RB 170
J 4-5
Frost protection temp. (Chap. 6.7.5)
J 6
No function
J 7
Jumper 7 open: Ventilation level 3 is
reset after an hour.
J 8
RB-ZF4 or RB-D1-ZF4 room air
control active: Leave factory setting,
J8 must be bridged.
J 9
Jumper 9 open: The ventilation unit
can be switched off at the room air
control. Jumper 9 bridged:
RB-ZF4: Switch-off function blocked
RB-D1-ZF4: Ventilation unit runs in
"Humidity protection ventilation" ven-
tilation level in OFF switch position.
RFS or CO
J10
Jumper 10 bridged: CO
RFS-sensor activated. Without a
sensor, jumper 10 must be open.
0...10 V input for CO
sensor blocked
Further connection options
W3
Connection cable (provided by cus-
tomer) for external operating display.
k1
Potential-free relay contact (max.
3 A / 250 V AC, 2 A / 30 V DC).
The contact is closed when the
ventilation unit is running.
Connection cable (provided by cus-
W4
tomer) for external CO
RFS sensor.
W5
Connection cable (provided by
customer) for external differential
pressure controller.
Differential pressure controller with
potential-free relay contact. Minimum
switching power of relay contact:
230 V AC/2 A. Remove J1 bridge on
A2 control circuit board.
Connection cable (provided by
W6
customer) for external supply air
temperature sensor
Remove resistor 12k on GW1
circuit board
or VOC sensor.
2
-, VOC- or
2
/VOC/ RFS
2
or VOC or
2
NTC 15.
.