Technical Data

Voltage
[V]
Frequency
[Hz]
Power
[W]
Temperatur
[°C]
[°F]
Air flow (20°C)
[l/min]
[cfm]
Air pressure
[mbar]
Weight with cord (3 m)
[kg]
[lbs]
Dimensions L x Ø
[mm]
Protection class
Noise level L
[dB]
pA

Product Features

1. Mains switch 2. Potentiometer for temperature adjustment 3. Switch for air volume control 4. Pipe of the heating
element 5. Protective grid 6. Screw 7. Nozzle* 8. Handle 9. Air filter 10. Mains connection 11. Air slide

Intended Use

When observing the safety instructions and using original Leister accessories, this hot air tool is suitable for all hot
air applications listed in these operating instructions.
Applications
Soldering and unsoldering of SMD and wired components.
Welding of thermoplastic polymers as well as individual elastoplastics and elastomer bitumen or asphalt in the
shape of plates, pipes, profiles, sealing material, coated fabrics, foils, foams, tiles and sheathing. The following
welding procedures are possible: Overlap, wire, band, heating element and fusion welding.
Drying of moist surfaces
Shrinking of heat-shrinkable tubing or sleeves, foils, sheathing, solder connectors and form components.
Heating for forming, bending and coupling of thermoplastic components
Defrosting frozen water lines
Activating/dissolving solvent-free and hot-melt adhesives
Sterilization of laboratory and glassware as well as medical instruments
Soldering of copper tubing, solder connectors and metal foils
Igniting of wood chips, paper, coal or straw in furnaces
Dehorning of calves (only with 24V~ special version!)

Mounting t he Nozzle*

Touching a hot nozzle can lead to serious burns. Before attaching or replacing a nozzle, allow the unit to cool
down completely or use a suitable tool.
A falling down nozzle can set an object on fire. Nozzles must be mounted firmly and secure on the unit.
A hot nozzle can set a surface on fire. Place down hot nozzles only on fire-proof surfaces.
An incorrect or defective nozzle can lead to heat accumulation and damage the unit. Use only original noz-
zles according to the table that are suitable for your unit.
Slide the nozzle 7 onto the heating-element tube 4 and tighten the screw 6.
* Nozzles not included in the delivery scope!
Translation of the Original User Manual
English - 9 -
100
1500
300 (Step 2)
195 x 85 x 160, Handle Ø 57
GHIBLI
120
200
50/60
1500
1500
20 – 600
70 – 1100
10.6
15
1.2
2.6
II/
(Double insulated)
70
230
2000
350 (Step 3)
12.4
21