Water Test the System (cont.)
Fill the footbath basin at least 3" (7.6 cm) above the top of the suction cover.
Turn on the unit for about five minutes and check all visible connections for leaks. Turn the unit off.
Open the tower and inspect all piping connections for leaks.
Check the connections on the back surface of the face wall and check all wall and floor joints for
leaks.
Close the tower. Securely wrench tighten the two 3/8" bolts. Do not overtighten.
CHECK POINT # 11.
Confirm that:
¤
All connections are tight.
¤
The footbath has been filled with water to 3" (7.6 cm) above the top of the suction cover.
¤
The unit has been run and the connections have been checked for leaks.
¤
The tower has been opened, checked for leaks, closed and secured.

21. Clean Up After Installation

Clean the system room with a mild non-abrasive detergent and warm water. Do no use abrasive
cleansers.
Remove stubborn stains and paint from the tower surfaces with turpentine or paint thinner. Remove
dried plaster by carefully scraping with a dull-edged piece of wood. Do not use metal scrapers, wire
brushes or other metal tools.
Remove residual plaster by applying a powder-type detergent to a clean, damp towel to provide
mild abrasive action.

22. Troubleshooting Procedures

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
1.
System does not start or
stop.
2. Water flow surges.
1030200-2-C
Probable Causes
A. No power to
pump/receptacle/keypad.
B. Harness is blocked.
C. Keypad disconnected from
pump/control box.
D. Keypad does not work.
E. Not enough water in footbath
basin.
F.
Motor/pump assembly does not
work.
G. Control does not work.
A. Not enough water in footbath
basin.
B. Suction is blocked.
C. Harness is blocked.
Recommended Action
A. Set/Reset GFCI or ELCB. Check
wiring. Refer to installer/dealer.
B. Remove blockage.
C. Reconnect keypad and/or wiring
harness.
D. Replace keypad. Refer to
installer/dealer.
E. Fill basin 3" (7.6 cm) over top of
suction cover.
F.
Replace motor/pump assembly.
Refer to installer/dealer.
G. Replace control. Refer to
installer/dealer.
A. Fill basin 3" (7.6 cm) over top of
suction cover.
B. Remove obstruction.
C. Remove blockage.