16. Install the Keypad

Mark the hole location for the keypad between 58" (147.3 cm) and 60" (152.4 cm) above the footbath
basin. If the keypad will be installed to tile, center the mark on a tile.
Refer to illustration above. Drill a 3/16" diameter hole at the top center as shown. Use a 1-5/8"
carbide hole saw to carefully cut the larger hole through the finished wall material, cement board
and waterproofing material.
Slip the gasket onto the housing. Apply a generous, continuous bead of clear, high-quality silicone
sealant to the back of the keypad housing and the gasket. Insert the housing into the hole and
loosely thread the plastic nut to the housing from the back.
Check to be sure the keypad is properly aligned and securely tighten the plastic nut from behind.
NOTE: The outer ring on the keypad must rotate freely.
Remove any excess sealant.
Locate the wire harness connection labeled "keypad". Align and press this connection into the back
of the keypad.
NOTE: National electrical code requires that you permanently separate the high and low voltage cables.
Create a drip loop in the cable.
Connect the two wire harnesses to the control by aligning them and pressing in place. One wiring
harness connects the keypad to the control; the other connects the tower to the control.
CHECK POINT # 8.
Confirm that:
¤
The finished basin, wall and ceiling materials are installed.
¤
The suction assembly is installed, with silicone sealant applied to all the threads and
areas the suction flange contacts.
¤
The suction cover fits flat against the basin wall.
¤
The silicone sealant has fully cured.
¤
The keypad is installed and sealed with silicone sealant and rotates freely.
Kohler Co.
Control
Housing
Gasket
Install switch 58" (147.3 cm)
to 60" (152.4 cm) above
footbath basin.
Hole Pattern
Nut
Wire Harness
3/8" (1 cm) D.
(Drill First)
1-5/8" (4.1 cm) D.
(Drill Second)
23