Maintenance and cleaning

Disconnect the power plugs of all other units in the water prior to starting work on the unit (I)!
Cleaning the unit (L, M, N):
– To open, release the nozzle holders (9) by slightly turning it at the housing top section (10) and remove.
– Unscrew the LED light nozzles (11) and, if fitted, the extension tubes (6) (see Fig. C).
– Laterally slide the respective pump (26) out of the engagement holder of the filter basket (27).
– Slightly turn the pump cover to disengage (28), then remove the impeller (29).
– Clean all components under running water using a brush.
Reassembling the unit:
Reassemble the unit in the reverse order (L, M, N).
Note: Push the pump housing into the filter basket until it tangibly engages.
Battery change in the manual transmitter (O, P):
Improper handling can lead to damage to the manual transmitter!
Touch a bare metal surface (e.g. a radiator) to discharge static charges, which could lead to damage to the
internal components of the manual transmitter!
Ensure that neither dirt nor moisture can enter the manual transmitter!
– Guide a slot screwdriver (30) into the lateral opening (31) of the manual transmitter.
– Open the manual transmitter housing by slightly turning the screwdriver, then remove the housing bottom sec-
tion (32).
– Pull the battery (33) out of the holder (34).
– Push the new battery into the holder (34). Ensure that the embossed side (35) of the battery points upward.

Remedy of faults

Malfunction
Pumps do not start
Unit does not respond to manual transmitter
Insufficient fountain height
Unit switches off after a brief running time (ap-
prox. 10 s)
Cause
No mains voltage
Manual transmitter not taught in
Impeller blocked or soiled
Pump strainer casing soiled
Nozzles soiled
Water temperature too high
Pumps run dry
Remedy
Check mains voltage
Check supply lines
Teach-in manual transmitter
Clean impeller
Clean strainer casing
Clean nozzles
Note maximum water temperature of + 35°C.
For switching on again, pull the power plug and
reinsert in the socket.
Check water level and, if necessary, top up the
water. For switching on again, pull the power
plug and reinsert in the socket.