KNOW YOUR FLOW

A SIMPLE METHOD
THE DOSATRON IS COMPOSED OF
2 clicks = 1 motor cycle
= The stroke volume
The speed of the motor is proportional to the flow of water passing through
the system.
Calculation of water flow in l/h=
Number of clicks in 15 seconds
2 clicks = 1 cycle
Calculation of water flow in GPM=
Number of clicks in 15 seconds
2 clicks = 1 cycle
NOTA :
This method of calculation cannot replace a flow meter. It is given
only as an approximate guide.
In its up and down movement,
you can hear the motor piston click:
volumetric
hydraulic
motor piston
connected
to:
a dosing
piston
Once in the up
2
2
©
DOSATRON INTERNATIONAL / 49
:
down position
position
Calculation for
1 minute
=
x
4 x 60 x
Calculation for 1 hour
Calculation for
1 minute
=
4 x 1.7 ÷
x
Stroke volume in litres
Once in the
Stroke volume
in liters
1.7