Product Conformity And Certifications - Festo CMMO-­ST DION Série Description Et Mode D'emploi

Masquer les pouces Voir aussi pour CMMO-­ST DION Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CMMO­ST-...-DION/DIOP
Auxiliary supply +24 V DC, LOGIC OUT [X3.1]
Nominal voltage
– Supplied via [X9]
– not additionally filtered or
stabilised
Nominal current
Overload protection
Tab. 13
Technical data: Electrical data of the auxiliary supply output
Signal lines
Max. cable length
Cable cross section
Tab. 14
Technical data: Cabling at [X3]
4.3

Product conformity and certifications

Product conformity and certifications
CE marking (declaration of conformity
è www.festo.com)
Certifications
1) The component is intended for industrial use.
Tab. 15
Product conformity and certifications
Requirements for complying with the certified UL conditions if the product is operated in
the USA or Canada can be found in the separate UL documentation.
38
[V DC] 24
[mA]
100 (max.)
not overload-proof
[m]
30
[mm²]
0.14 ... 0.5
according to EU Machinery Directive 2006/42/EC
according to EU EMC Directive 2014/30/EU
c UL us - listed (OL)
RCM (Regulatory Compliance Mark)
Festo – GDPC-CMMO­ST-EA-S1-Z6 – 2017-05d – English
1)

Publicité