Carat DS-4000 Mode D'emploi page 45

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
FLUSH CUTTING KIT LIST OF CONTENTS
1. Flush Cutting Flange
2. Socket Cap Arbor Bolt & Washer
3. Flat-Head Socket Cap Screws x 6
4. M5 L-Hex Wrench
5. M8 L-Hex Wrench
FLUSH CUTTING KIT ASSEMBLY
To mount the flush cutting kit, first remove the standard arbor bolt, flanges and blade .
1.
Mount the flush cutting flange on the spindle and secure with the washer and socket cap arbor bolt.
Engage the arbor lock tighten the arbor bolt securely using the M8 L-hex wrench.
2.
Mount the flush cut blade on the flange, align the holes and thread in the flat-head socket cap screws.
Using the M5 L-hex wrench, tighten the screws evenly and diagonally.
FLUSH CUTTING KIT OPERATION
1.
Remove the the water hose from water nozzle on the outer blade
guard and connect it to the alternate water nozzle on the inner
blade guard.
2.
Remove the 6 screws securing the outer blade guard .
3.
Unclip the 3 toggle latches and pop the loose hasps in the plastic
clips to prevent rattling.
4.
Lift away the outer blade guard and keep in a safe place.
5.
Once the flush cutting operation is completed, immediately
replace the outer blade guard and water hose.
WARNING: Always operate with the outer blade guard in place while performing standard cutting.
Never operate the saw with the outer blade guard removed except for flush cutting operations.
WARNING: Check the tightness of the mounting screws and arbor screw periodically.
WARNING: If any unusual vibration is felt in operation, stop immediately and find the cause before
continuing.
OVERLOAD PROTECTION, OVERHEAT PROTECTION
Overload & Load Warning Lamp
When full load is reached, the load warning lamp will flash red. If full load
is exceeded and sustained for too long, the motor will shut down and the
load warning lamp will glow solid red. In this case, the motor must be first
shut off and then restarted.
Overheat Thermal Protection
If the temperature of the motor gets too high, the thermal protection
will shut the motor down. The switch must be first shut off and then restarted. When this happens, do not
GB