3.4

AUDIO CIRCUIT

Notes:
• This adjustment should be done after the "REC color
(colour) level adjustment" for the video circuit has
been completed.
• GND (Ground) should be taken from the Tuner shield
case.

3.4.1 Audio REC FM

Signal
Mode
Equipment
Measuring point (D)
External trigger
EVR mode
EVR address
Specified value
Adjustment tool
(1) Apply the external trigger signal to D.FF (E) to observe
the Audio PB FM waveform at the measuring point (D).
(2) Record the signal (A3) with no audio signal input in the
mode (B), and play back the recorded signal.
(3) Press the channel buttons (+, –) simultaneously to enter
the manual tracking mode. This also brings tracking to
the center (centre).
(4) If the A.PB FM level is not within the specified value (G1),
perform the adjustment in a following procedure.
(5) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(6) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(7) Adjust with the channel buttons (+, –) on the VCR (or on
the remote controller) so that the A.PB FM level of the
higher channel level becomes the specified value (G1).
(Adjust before recording, then confirm it by playing back.)
(8) If the specified value (G1) is not obtained, adjust with the
channel buttons (+, –) so that the waveform level of the
lower channel level becomes the specified value (G2).
(Adjust before recording, then confirm it by playing back.)
(9) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
Specified
value (G2)
(A1)
• Ext. input
(A2)
• Audio: No signal
(A3)
• Video: Color (colour) bar signal [PAL]
(B)
• S-VHS LP
(C)
• Oscilloscope
• TP2253 (A. PB. FM)
(E)
• TP111 (D.FF)
(F1)
• Jig RCU: Code "57"
(F2)
• A: 30 (Press remote controller "3" and
"0" keys.)
(G1)
• 450 ±100 mVp-p
(G2)
• More than 300 mVp-p
(H)
• Jig RCU [PTU94023B]
• Digit-key remote controller
V. rate
Fig. 3-4-1a
Audio REC FM
Published in Heiloo Holland
3.5

PAL/SECAM CONVERTER CIRCUIT

Note:
• Unless otherwise specified in this P/S Converter cir-
cuit adjustments, all measuring points and adjustment
parts are located on the P/S Converter board.
3.5.1

fH VCO

Signal
Mode
Equipment
Measuring point (D1)
Short point
Adjustment part (F)
Specified value
(1) Connect the short wire between the short point (D2) and
the GND (Ground).
(2) Observe the waveform appeared at the measuring point
(D1).
(3) Adjust the adjustment part (F) so that the fH SYNC fre-
quency becomes the specified value (G).
(4) Disconnect the short wire between the short point (D2)
and the GND (Ground).
FH–SYNC

3.5.2 DEMOD Fo

Signal
Mode
Equipment
Measuring point (D1)
Adjustment part (F1)
Specified value
(1) Observe the B-Y waveform at the measuring point (D1).
(2) Adjust the adjustment part (F1) so that the difference be-
tween the blanking level and the pedestal level of the B-
Y waveform becomes the specified value (G).
Specified
value (G1)
Specified value (G)
Pedestal level
B – Y signal
(3) Observe the R-Y waveform at the measuring point (D2).
(A1)
• Ext. input
(A2)
• Color (colour) bar signal [SECAM]
(B)
• EE
(C)
• Oscilloscope
• IC3504 pin 4 (H OUT)
(D2)
• TP3503
• VR3501 (FH FREE RUN ADJ.)
(G)
• fH = 15.625 ± 0.2 kHz
(T = 64 ± 0.8 µsec)
Specified value (G)
Fig. 3-5-1a
fH VCO
(A1)
• Ext. input
(A2)
• Color (colour) bar signal [SECAM]
(B)
• EE
(C)
• Oscilloscope
• TP3501 round (B-Y)
(D2)
• TP3502 round (R-Y)
• L3513 (SECAM DECODE ADJ.)
(F2)
• VR3502 (SECAM DECODE ADJ.)
(G)
• Less than 20 mVp-p
Blanking level
Fig. 3-5-2a
DEMOD Fo-1
8/6/2016
H.rate
H.rate
3-5