Digi-Trac™ Control System Error Messages - Titan IMPACT 640 Notice D'utilisation

Masquer les pouces Voir aussi pour IMPACT 640:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Digi-Trac™ control System Error messages
The following error message screens appear whenever the Digi-Trac
Control System detects a problem with the sprayer. Once a problem
occurs and the error message appears, the sprayer will shut down.
Before proceeding, follow the Pressure relief
Procedure outlined previously in this manual.
additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. always unplug the sprayer before
servicing!
check Transducer Screen
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take the sprayer to a Titan authorized
service center for repair.
check Potentiometer Screen
The Check Potentiometer screen appears
when the potentiometer has become
disconnected or is defective. Take the
sprayer to a Titan authorized service
center for repair.
Low Voltage Screen
The Low Voltage screen appears when
the sprayer shuts down because of low
input voltage. Check the power supply
and correct the problem. Restart the
sprayer by following the "Painting"
procedure in the Operation section of this
manual.
High motor Temperature Screen
The High Motor Temperature screen
appears when the temperature of the
motor has risen too high. Take the
sprayer to a Titan authorized service
center for repair.
High mechanical Load
The High Mechanical Load screen appears
when the sprayer shuts down because
of high current or when the sprayer goes
into current fold back mode. Take the
sprayer to a Titan authorized service
center for repair.
High control Temperature
Indicates the Digi-Trac is shut down due
to excessive heat. Take the sprayer to a
Titan authorized service center for repair.
check motor
Indicates the motor is shut down due to
connection problems between the motor
and controller. Take the sprayer to a Titan
authorized service center for repair.
Bad Hall cycle Power
Indicates the motor or motor hall affect
sensors are defective. Take the sprayer
to a Titan authorized service center for
repair.
© Titan Tool Inc. All rights reserved.
CHECK TRANSDUCER
CHECK
POTENTIOMETER
LOW VOLTAGE
HIGH MOTOR
TEMPERATURE
HIGH MECHANICAL
LOAD
HIGH CONTROL
TEMPERATURE
CHECK MOTOR
BAD HALL CYCLE
POWER
15
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

805-002805-004805-005

Table des Matières