If no humidity sensor is connected, a scale of 0 to 10 is used, where 0 means that the steam function on the Combi
heater is switched off, and 10 means that it is operating continuously at full power. The numbers between 0 and 10 on the
scale indicate that the steam function will operate for a certain amount of time before switching off for a certain amount
of time. The total cycle time is about 4 minutes and 20 seconds. Approximate times for the various scale steps:
RH
On
0
0
4 mins 20 secs
1
1 min 52 secs
2 mins 28 secs
2
2 mins 09 secs
2 mins 11 secs
3
2 mins 25 secs
1 min 55 secs
4
2 mins 41 secs
1 min 39 secs
5
2 mins 57 secs
1 min 23 secs
6
3 mins 14 secs
1 min 06 secs
7
3 mins 29 secs
0 mins 51 secs
8
3 mins 45 secs
0 mins 35 secs
9
4 mins 01 sec
0 mins 19 secs
10
4 mins 20 secs
Due to international regulations, when a temperature or humidity sensor is connected certain temperature/humidity com-
binations cannot be used. For example, if the temperature is 80 °C it is not possible to set the %RH to greater than 21%.
The control panel handles this automatically. Regardless of how you adjust the temperature and humidity, the control
panel will ensure that the maximum values are not exceeded.
The maximum air humidity setting is 70 RH%.