Environmental Protection Measures - Nice mindyA500 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
10) Servicing:
The card, being electronic, needs no particular maintenance.
However, make sure the device that controls the motor overload cut-
out is in perfect working order and well adjusted at least twice a year;
adjust with the trimmer if necessary.
10.1) Information on environmental protection measures:
This product is made from various kinds of material, some of which
can be recycled.
10.2) Technical features of the control unit:
Mains power
Max. current to motors
Auxiliaries output
Phototest output
Flashing light output
Gate open Light output "SCA"
Working time
Pause time
Operating Temperature
: 400 Vac or 230 Vac ± 10%, 50 or 60Hz
: 4A
: 24Vac, max. current 200mA (400mA if Phototest is not used)
: 24Vac, max. current 200mA
: For 230Vac flashing lights, max. power 40 W
: For Light 24Vac, max. power 2 W
: Adjustable from <3 to>120 s, or from <90 to>210 s with TLM
: Adjustable from <5 to>200 s
: -20 ÷ 70 °C
Check the safety devices (photoelectric cells, pneumatic edges, etc.)
and the flashing light are in perfect working order
Recycle or dispose of the product in compliance with current laws
and by-laws.