Automatic hot air welding machine
Application
• Welding of PVC coverings and melt welding of linoleum floor coverings.
Warning
Caution
230
120
FI
(Translation of the original operating instructions)
Danger! Unplug the tool before opening it, as live components and connections
are exposed.
Incorrect use of hot air tools can present a fire and explosion hazard, particularly
in the proximity of flammable materials and explosive gases.
Danger of getting burned! Do not touch the heater tube and nozzle when they are
hot. Let the tool cool down. Do not point the hot air flow in the direction of people
or animals.
Only connect the tool to a receptacle with protective earth conductor. Any
disconnection of the protective earth conductor, in or outside the tool is dangerous!
Only use extension lead with protective earth conductor.
The rated voltage stated on the tool must correspond with the mains voltage.
For personal protection, we strongly recommend the tool to be connected to an
RCCB (Residual Current Circuit Breaker) before using it on construction sites.
The tool must be operated under supervision.
Heat can ignite flammable materials which are not in view.
Protect the tool from damp and wet.