Insert the empty dust container "CYCLONE" to
vacuum cleaner. The characteristic "click" indicates that
container has been mounted correctly.
Emptying the dust container "CYCLONE" is necessary
when you notice that:
a) "CYCLONE" dust container full indicator indices
turned on,
b) sucking power of vacuum cleaner decreased,
c) dust container "CYCLONE" is full.
Disassembly of filters
In case of dirty filters: inlet filter, foam
filter (15), HEPA inlet filter (14), outlet
foam filter (13), "Microfilter" (12) you can
replace them with new filters, clean them or
rinse with running water.
Do not wash the filter in the washing machine or
dishwasher.
Filters can be dried in natural way only.
Do not dry the filters using hairdryers,
on heaters and radiators.
Before replacement of filters make sure
that vacuum cleaner is switched off and
connection cable plug is pulled out from
the wall outlet.
INLET FILTER HEPA AND FOAM INLET
FILTER
Vacuum cleaners are equipped with inlet filter HEPA
type H13.
It is necessary to clean periodically the inlet filter HEPA
(14) in order to remove minor fractions of the dust, and
foam inlet filter (15) must be also cleaned.
Disassembly the "CYCLONE" dust container and empty
it in accordance with paragraph
1
Remove the HEPA foam inlet filter (14) from
"CYCLONE" dust container.
2
Remove foam inlet filter (15). If the foam inlet filter
(15) is dirty, you can replace it with a new filter, you can
clean it or rinse with running water. Do not forget to dry
above mentioned filter before re-installation.
The main function of the foam inlet filter (15) is to
protect HEPA inlet filter (14) against excessive dirt.
D
C
.
For safety reasons it is unacceptable to
install the moist or damaged foam inlet
filter (15).
● Clean the pleats of HEPA inlet filter (14), in case
of filter damage it should be absolutely replaced
with a new filter. If HEPA inlet filter (14) is dirty, you
can replaced it with a new filter, you can clean it or
rinse with running water. Do not forget to dry above
mentioned filter before re-installation.
For safety reasons it is unacceptable to
install the moist or damaged inlet filter
HEPA (14).
● Insert a new/rinsed inlet foam filter (15) into
previously occupied space.
3
Insert a new/rinsed HEPA inlet filter (14) to the dust
container into previously occupied space.
4
Insert "CYCLONE" dust container with mounted
HEPA inlet filter (14) to vacuum cleaner chamber. The
characteristic "click" indicates that container has been
correctly mounted.
It is recommended to replace HEPA inlet
filter (14) with a new one every 6 months
of use.
Do not vacuum without HEPA inlet filter
(14) installed in "CYCLONE" dust
container. Lack of HEPA inlet filter (14)
shall prevent insertion of "CYCLONE" dust
container to the vacuum cleaner.
"MICROFILTER" OUTLET FILTER
AND OUTLET FOAM FILTER
1
In order to replace "Microfilter" outlet filter (12)
press the hook located in the filter cover and pull out
the filter cover from vacuum cleaner.
2
Pull out the "Microfilter" outlet filter (12).
If the "Microfilter" outlet filter (12) is dirty, you can
replace it with a new filter, you can clean it or rinse with
running water. Do not forget to dry above mentioned
filter before re-installation.
For safety reasons it is unacceptable to
install the moist or defective "Microfilter"
outlet filter (12).
E