Heat pump water heater - TECHNICAL INFORMATION FOR INSTALLERS
(C) Values obtained from average results of three tests carried out with external air temperature of 7°C and relative humidity at
87%, inlet water temperature of 10°C and temperature set according to the provisions set forth in 2014/C 207/03 - transitional
methods of measurement and calculation and EN 12102). Rigid Ø200 ducted product.
(D) Value that ensures correct operation and eases maintenance if the product is not ducted.
(E) Outside the operating temperature range of the heat pump, heating of the water is ensured by the integration.
(F) Values obtained with external air temperature of 20°C and relative humidity at 37%, inlet water temperature of 10°C and set
temperature of 52°C (according to the provisions set forth in EN 16147). Product not ducted.
(G) Values obtained with external air temperature of 20°C and relative humidity at 37%, inlet water temperature of 10°C and set
temperature of 52°C (according to the provisions set forth in 2014/C 207/03 - transitional methods of measurement and
calculation). Product not ducted.
Data collected from a significant number of products.
Additional energy data are shown on the Product Sheet (Attachment A) that is an integral part of this manual.
Products which do not have the label and data sheet required for boiler/solar power configurations pursuant to regulation 812/2013
may not be used in such installations.

TECHNICAL INFORMATION FOR INSTALLERS

3. WARNINGS

3.1 Installer qualification

WARNING! The installation and initial start-up of the appliance must be performed by qualified personnel in
compliance with the national regulations in force regarding installation, and in conformity with any regulations
issued by local authorities and public health bodies.
The water heater is supplied with a sufficient amount of R134a refrigerant for its operation. This refrigerant fluid does
not damage the atmosphere's ozone layer, is not flammable and does not cause explosions; however any maintenance
activities or work on the refrigerant circuit must exclusively be carried out by authorised personnel with the suitable
equipment.

3.2 Implementing the instructions

WARNING! Incorrect installation can harm persons or animals and damage possessions; the manufacturer
shall not be held liable for any damage in such cases.
The installer is required to observe the instructions outlined in this manual.
Once installation is complete, it is the installer's duty to inform and instruct the user on how to operate the water heater
and carry out the main operations correctly.

3.3 Safety regulations

Refer to Paragraph 1.1 under the section GENERAL INFORMATION for the description of the symbols used in the table
below.
Ref. Warning
Protect connection piping and cables so as to
1
avoid them being damaged.
Make sure the installation site and any
systems to which the appliance must be
2
connected fully comply with the regulations in
force.
Use manual tools and equipment that are
3
suitable for the intended use (in particular,
ensure that the tool is not worn and that the
Type of risk
Electrocution caused by exposure to live
wires.
Flooding due to water leaking from
damaged pipes.
Electrocution from contact with live wires
that have been incorrectly installed.
Damage to the appliance caused by
improper operating conditions.
Personal injury caused by flying splinters or
fragments, inhalation of dust, knocks, cuts,
puncture wounds and abrasions.
65
Symbol