Time Setting; Information Menu; Installer Menu - Ariston 200 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Heat pump water heater - OPERATING AND MAINTENANCE INSTRUCTIONS FOR THE USER

7.5 Time setting

The time setting is required:
At initial start-up;
Occur simultaneously absence of power from the mains and battery
(the product will restart in Auto mode).
You can also change the current time through the parameter P1 (paragraph 7.7).
The display flashes up showing hours and minutes. Turn the knob until you find the
current time and confirm by pressing the knob. Repeat the procedure to set the
minutes.

7.6 Information menu

The information menu allows for visualising data for monitoring the product.
To enter the menu, press the relative knob and hold for 5 seconds.
Turn the knob to select the parameters L1, L2, L3 ... L9
Upon reaching the desired parameter, press the knob to visualise its value. Press the
knob or "MODE" button to return to the parameter selection area once again.
To exit the information menu, press the "mode" button (the appliance will ensure that the menu is
automatically exited after the latter has been idle for 10 minutes).
Name
Parameter
L1
T W1
L2
T W2
L3
TW3
L4
T AIR
L5
T EVAP
L6
HP h
L7
HE h
L8
SW MB
L9
SW HMI

7.7 Installer menu

CAUTION: THE FOLLOWING PARAMETERS MUST BE ADJUSTED BY QUALIFIED PERSONNEL.
Several of the appliance's settings can be modified through the installer menu. The
maintenance symbol is visualised on the left.
To enter the menu, keep the knob pressed for 5 seconds then scroll the
parameters of the "L – INFO" menu until reaching "P1".
After entering the code (illustrated in the table that follows), turn the knob to select the
parameters P1, P2, P3 ... P8
Upon reaching the parameter to be modified, press the knob to visualise the
parameter's value then turn the knob to set the desired value. To return to the
parameter selection area, press the knob to store the entered parameter or press
"mode" (or wait 10 seconds) to exit without storing the entered value.
To exit the installer menu, press the "mode" button (the appliance will ensure
that the menu is automatically exited after the latter has been idle for 10 minutes).
Name
Parameter
Temperature recorded by the heating element unit sensor 1.
Temperature recorded by the heating element unit sensor 2.
Temperature recorded by the hot water pipe sensor.
Temperature recorded by the inlet air sensor.
Temperature recorded by the evaporator sensor.
Meter for internal parameter 1.
Meter for internal parameter 2.
Mainboard software version.
Interface board software version.
Parameter description
Parameter description
75

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

240240 sys

Table des Matières