Electrical Connection

This appliance must be installed by a qualified electrician
to comply with the relevant Institute of Electrical Engineers
(I.E.E.) regulations and also the local electricity supply
company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double pole
switch having a contact separation of at least 3mm in all
poles. This cooker must not be connected to an ordinary
domestic power point.
The total electrical load of the appliance is approximately
3.6kW. The cable size used should be suitable for this load and
comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (Fig.7-15 and Fig.7-16). Check that the links are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
These appliances are of type X with regard to protection
against over heating of the surrounding surfaces.
Hotplate
Check each burner in turn. There is a flame safety device that
stops the flow of gas to the burner if the flame goes out. For
each burner, turn the control knob to the solid flame symbol.
Press in the control knob. This lets gas through to the burner.
Keep holding the knob pressed in and press the igniter
button or light with a match. Keep holding the control knob
pressed in for about 10 seconds.
If when you let go of the control knob the burner goes out,
the safety device has not held in. Wait one minute then try
again this time holding the control pressed in for slightly
longer.

Oven check

Turn on the oven and check that it starts to heat up.
Check that the oven lights are working.
Note: The oven light bulb is not included in the guarantee.
Turn off the oven.
L1
N
L3
L2
ArtNo.000-0011 Electrical connections 3-phase
3N ac
230/400V 50Hz
21
ArtNo281-0025 Albertine 1 Phase DF
L1 L2 L3
N
Fig.7-15
Fig.7-16