ePump™ and VS-FloPro™ Variable-Speed Pump Controller
waRnInG
ElECTRICal ShOCK haZaRD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit before starting the procedure.
Failure to comply may cause a shock hazard resulting in
severe personal injury or death.
2.
Install the normally-closed fireman's switch to the
timeclock assembly. (See timeclock manufacturer's
instructions for details.)
3.
Connect the main timeclock contacts to the booster
pump power input per the booster pump installation
manual.
4.
Connect one side of the fireman's switch to the
Controller at J3 REMOTE CONTROL, COMMON.
5.
Connect the other side of the fireman's switch to the
controller at J3 REMOTE CONTROL, INPUT 4.
6.
Set the timeclock to the desired on/off times.
7.
Turn on all switches and the main breaker feeding
power to the variable-speed pump.
8
If the installation is working properly, the fireman's
switch will open 20 minutes before the booster pump
shuts down, the variable-speed pump will continue
to run for 30 minutes, and the Controller will display
PUMP wIll REMaIn On FOR xx:xx, where
xx:xx is the time remaining until variable-speed
pump shutdown.
Section 3. User Operation of the
Variable-Speed Controller
The variable-speed controller contains an advanced
microcontroller that provides a simple yet sophisticated
interface to operate your variable-speed pump for maximum
efficiency and enjoyment of your pool.
The controller allows operation of the variable-speed pump in
three ways: Manually, from built-in timers, and remotely via
contact closures.
3.1

The Controller Interface

The controller interface panel provides both timed and
manual speed controls for the variable-speed pump.
Four (4) speeds are directly available on the panel, while four
additional speed presets may be accessed via the
MEnU key.
The up and down keys are used to adjust the pump speed.
Speed is saved as it is adjusted. No further action is required
to save the new speed setting after adjustment.
As shown below, preset speed "
feature. Hence, it is intended to be assigned an energy-
efficient filtration speed, as determined by the installer.
3.2

basic Functions

The controller has two (2) operational modes: User Mode and
Setup Mode.
" is assigned to the eStar
|
Installation Manual
User Mode
In the User Mode, the controller provides access to pump
control options including:
• Manual start and stop of pump
• Pump speed setting
• Timeclock setup and operation
Setup Mode
The Setup Mode allows the user to configure the controller.
Setup options include:
• Time-of-day setting
• Labeling of pump speeds
• Display light control
• Language selection
• Run duration
3.3

OFF Mode

When the pump is off, the controller displays
PRESS SPEED OR MEnU/00:00 PUMP IS OFF, where
00:00 is the time-of-day clock.
PRESS SPEED OR MENU
12:00AM
2
3.4

RUn Mode

When the pump is running, the controller displays
n:labEl/00:00 RPM:xxxx, where n:label is the number
and label of the selected speed, 00:00 is the time-of-day
clock, and xxxx is the pump speed.
10:00AM
2
ENGLISH
Page 11
PUMP IS OFF
3
4
MENU
2:SPEED 2
RPM: 1200
3
4
MENU