Commissioning
Code
No.
Name
Serial baud rate
c25
Actual PI setpoint
c38
Frequency setpoint
c40
via keys
or Modbus
Start condition
c42
(with mains on)
Mode selection for c61
c60
Present status/error
c61
Last error
c62
Last error but one
c63
Configuration TRIP
c70
reset (error reset)
Auto-TRIP reset delay
c71
Operating time
c78
counter
Mains connection
c79
time counter
PI setpoint
c81
S-ramp integration
c82
time
Minimum feedback
c86
Maximum feedback
c87
18
Possible Settings
Selection
Lenze
0
0
LECOM: 9600 bps
Modbus: 9600,8,N,2
1
LECOM: 4800 bps
Modbus: 9600,8,N,1
2
LECOM: 2400 bps
Modbus: 9600,8,E,1
3
LECOM: 1200 bps
Modbus: 9600,8,O,1
c86
0.0
0.0
{Hz}
1
0
Start after LOW-HIGH change at
terminal 28
1
Auto start if terminal 28 = HIGH
WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to
personnel! Automatic starting/restarting should only be used on equipment that is
inaccessible to personnel.
0
0
Monitoring only
1
Monitoring and editing
status/error message
error message
0
0
TRIP reset after LOW-HIGH
change at terminal 28, mains
switching, or after LOW-HIGH
change at digital input "TRIP reset"
1
Auto-TRIP reset
WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to
personnel! Automatic starting/restarting should only be used on equipment that is
inaccessible to personnel.
0.0
0.0
{s}
Display
Total time in status "Start"
Display
Total time of mains = on
0.0
c86
0.0
0.0
{s}
0.0
0.0
100
0.0
• See C01
• LECOM if C01 = 0...3
• Modbus if C01 = 8...11
c87
Display
500
Only active if C01 is set properly
(C01 = 1,5,7,9,11)
See also c70
c60 = 1 allows the keys
speed setpoint (c40) while monitoring c61
• Display
• Refer to Section 5 for explanation of
status and error messages
• Auto-TRIP reset after the time set in
c71
• More than 8 errors in 10 minutes will
trigger
60.0
See c70
0...999 h: format xxx
1000...9999 h: format x.xx (x1000)
10000...99999 h: format xx.x (x1000)
c87
50.0
• c82 = 0.0: Linear accel/decel ramp
• c82 > 0.0: Adjusts S-ramp curve for
smoother ramp
999
• Select feedback signal at C34
• If feedback is reverse-acting, set
999
c86>c87
Lenze 13466184 EDBSL03 v20 EN, DE, FR, IT, ES
IMPORTANT
to adjust
rSt
fault

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières