8/ Ph & Acl Sensors Cleaning; Important; 9/ Tri Pro Module Maintenance And Winterizing - Zodiac TRiPRO Notice De Montage

Masquer les pouces Voir aussi pour TRiPRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

pH
Recommended
values with
7,2 – 7,4
TRi PRO
Deactivate the
To increase
peristaltic pump
or add pH plus
Add pH minus
(automatic with
To reduce
TRi PRO
module)
Tests frequency
Weekly
(bathing season)
8/ pH & ACL sensors cleaning
To ensure that the TRi PRO module will operate under optimal conditions, it is recommended to clean
sensors (ph and/or ACL) before each calibration.
To clean a sensor :
- If the extremity of the sensor is covered with a greasy film (cosmetics deposit, sun lotion....), place it for
a few minutes in tepid soapy water. Do NOT use detergent products but rather a liquid dishwashing
product. Then rinse profusely using clear water.
- If the extremity of the sensor is covered with calcium buildup or if the above procedure was not
sufficient, place the sensor in a 10% hydrochloric acid solution for a few minutes (wear all necessary
protective clothing).Then rinse profusely using clear water.
Remark : It is possible to buy this acid cleaning solution from your local swimming pool retailer. Then
rinse profusely the pH tester with clear water and proceed with the calibration before using it.

IMPORTANT :

- Always clean pH & ACL sensors before performing a calibration.
- NEVER WIPE THE SENSORS WITH A CLOTH but shake it slightly in order to remove any excess
rinse water.

9/ TRi PRO module maintenance and winterizing

Using the TRi PRO module allows for more freedom when monitoring the pool parameters. However, it
is necessary to check a number of settings on a regular basis so as to ensure a correct and safe
operation of the system.
NOTE : Your TRi PRO module uses a peristaltic pump that is designed to release only pH minus. Do
NOT use hydrochloric acid, pH plus or any other chemicals.
TRi PRO module winterizing :
- When you want to winterize your TRi PRO module at the end of the season, it is recommended to let it
pump clear water instead of the pH minus so as to rinse out the peristaltic pipe.
TAC
Free chlorine
(total alcalinity or
buffer effect)
mg/L or ppm
°f (ppm)
8 – 15
0,5 – 2,0
(80 – 150)
Increase ACL set
Add alkalinity
point or use
corrector
'Boost' mode
(« TAC+ »)
Decrease ACL
set point
Add hydrochloric
or switch off the
acid
TRi unit
Weekly
Monthly
TH
Cyanuric
(calcium
acid
hardness)
(stabilizer)
°f (ppm)
mg/L or ppm
10 – 30
< 30
(100 – 300)
Add cyanuric
Add calcium
acid (only if
chloride
necessary)
Add calcium
Partially drain the
catcher or make
pool and refill
a decarbonation
with clear water
Monthly
Quarterly
Metals
Salt level
(Cu, Fe, Mn...)
3
g/L or kg/m
mg/L or ppm
≈ 0
4
Add salt
/
Leave it or
partially drain the
Add metals
pool and refill
catcher
with fresh water
Quarterly
Quarterly
39

Publicité

Chapitres

Table des Matières
loading

Table des Matières