3.7/ Automatic detection (« Plug & Play » TRi PRO module)
Zodiac TRi power pack will automatically detect the presence of a TRi PRO module. It will display 2
additional lines on the LCD screen, mentioning 'pH/ACL CONTROL' and 'pH' & 'ACL' set points.
1. After startup, 'pH/ACL CONTROL' will be displayed on the 3
2. pH & ACL set points will be displayed on the 4
right). In addition, a '^' symbol is displayed at the right of each set point value when measured value by
the appliance needs to be automatically corrected.
REMARKS :
3) pH regulation (peristaltic pump) is not activated as default setting and the LCD screen will
display as follows 'pH ---'. Activation will take place automatically approximately 8 hours
after it is turned on. To manually activate the pH regulation and display the set point on
the LCD screen, refer to the chapter 5 / 'Activating and deactivating the peristaltic pump'.
4) Displayed set point for ACL regulation is '1' as default setting.

3.8/ Testing / Priming the peristaltic pump

After installation it is recommended to test the peristaltic pump of the TRi PRO module and to prime it
(self-priming system).
WARNING ! Before testing the peristaltic pump, check that all the pH minus suction and injection
connections are correct. Always use appropriate safety clothes when handling chemical
products.
To test the peristaltic pump :
7. Turn on the TRi power pack ((ON/OFF) button).
8. Press the (MENU) button.
9. Use the (UP)/(DOWN) buttons to display 'pH\ACL SETUP'.
10.
Press (SELECT) to access the 'pH\ACL SETUP' menu.
11.
Use the (UP)/(DOWN) buttons to display 'TEST ACID'.
12.
A warning message will be displayed briefly, then press (SELECT) to start the pump test. The
peristaltic pump will run for approximately 30 seconds and will stop automatically. If you need to stop the
pump immediately, press on the (SELECT) button.
7. Check that the pump has been correctly primed (the pH minus liquid will be visible inside the
translucent piping).
NOTE : For a faster priming of the peristaltic pump, it may be necessary to repeat steps 2 to 7
several times depending on the length of the pH minus injection pipe.