3. Put the bottom part of POD clamp upside down onto dedicated piping place. Use a marker or a centre
punch to indicate the location of the 2 holes to be made in the pipe.
4. With provided hole saw (part #5), drill the 2 holes for POD supply. Ensure that the holes are perfectly
smooth around the edges.
5. Place the upper part of POD clamp onto the pipe, sliding it into the the previously drilled holes.
WARNING : Water flows through the POD in a certain direction. Please note the direction of the
6. Click the bottom part of the POD clamp onto the upper part already in place on the pipe. Use provided
reducer with « EU » mention for DN50 mm pipe. Do not use this reducer for DN63 mm pipe.
Reducer ("EU" mark) to be inserted
for DN50 mm pipe
7. Position the top part of POD sub-assembly with all its different elements onto the upper part of the
POD clamp (beware of the foolproof notch). Firmly tighten the locking ring (hand only tightening !).
arrows indicating the water flow before installing it!
Arrows indicating water flow
POD clamp without reducer for
DN63 mm pipe