Hitachi DS 14DVB Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
2. Insert the battery into the charger.
Firmly insert the battery into the charger till it
contacts the bottom of the charger and checking
the polarities as shown in Fig. 3.
CAUTION
If the batteries are inserted in the reverse direction,
not only recharging will become impossible, but it
may also cause problems in the charger such as
a deformed recharging terminal.
3. Charging
When inserting a battery in the charger, charging
Table 1
Before
Blinks
charging
(RED)
While
Lights
charging
(RED)
Charging
Blinks
complete
(RED)
Charging
Flickers
impossible
(RED)
Lights
Charging
(GREEN)
impossible
(2) Regarding the temperatures of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in the table below, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 2 Recharging ranges of batteries
Rechargeable batteries
EB14S, EB1414, EB14B
EB1814. EB18B. EB1820
EB14H, EB1430H, EB18H, EB1830H
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
Table 3 Charging time (At 20°C)
Charger
Battery
EB14S
EB1414, EB1814
EB14B, EB18B, EB1820
EB14H, EB18H
EB1430H, EB1830H
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
Temperatures at
which the battery
can be recharged
–5°C – 60°C
0°C – 45°C
UC24YFA
Approx. 35 min.
Approx. 40 min.
Approx. 50 min.
Approx. 55 min.
Approx. 70 min.
will commence and the pilot lamp will light
continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (At 1-second intervals.) (See
Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown
in Table 1, according to the condition of the charger
or the rechargeable battery.
NOTE
The charging time may vary according to
temperature and power source voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger firmly and pull out the battery.
NOTE
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
and normal time required for recharging will be
restored by recharging the batteries 2 – 3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
English
Malfunction
in
the
battery or the charger
The battery temperature
is
high,
making
recharging impossible.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ds 18dvb

Table des Matières