External Exhaust; Installing Hood Exhaust; Outside Top Exhaust (Example Only) - Beko MWOTR 30200 CSS Manuel D'utilisation

Masquer les pouces Voir aussi pour MWOTR 30200 CSS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

External exhaust

4

4.1 Installing hood exhaust

Read these instructions only if you
C
plan to vent your exhaust to the out-
side. If you plan to recirculate the air
back into the room, proceed to title 5
4.1.1 Outside top exhaust
(example only)
The following chart describes an example of one
possible ductwork installation.
Duct pieces
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance
with any vent hood.
If a rectangular-to-round transition
C
adaptor is used, the bottom corners
of the damper will have to be cut to
fit, using the tin snips, in order to al-
low free movement of the damper.
8 / 63 EN
Roof Cap
12 Ft. (3.6 m)
Straight Duct
(6"/15.2 cm
Round)
Rectangular-to-
Round
Transition Adap-
tor*
Over The Range Convection Microwave Oven / Installation Manual
x
Equivalent
Number
Length
used
24 Ft. (7.3 m)
x
(1)
12 Ft. (3.6 m)
x
(1)
5 Ft. (1.5 m)
x
(1)
Total Length
=
Equivalent
Length
=
24 Ft. (7.3 m)
=
12 Ft. (3.6 m)
=
5 Ft. (1.5 m)
=
41 Ft. (12.5 m)

Publicité

Chapitres

Table des Matières
loading

Table des Matières