Storch Airless ST 2000 Mode D'emploi page 187

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
Sprayer does not shut off
1. Perform Pressure Relief Procedure. Leave circulation
switch open and power switch OFF.
Troubleshooting Procedure
Connect an pressure gauge between the
device and the paint hose; connect the
sprayer to the power and set the on/off switch
to ON. Does sprayer reach or exceed its
maximum pressure?
YES
Disconnect the pressure sensor from the con-
trol board. Does motor stop running?
YES
Faulty pressure sensor. Replace and test with
a new one.
2. Remove control box cover so the control board status
light can be viewed if available.
Mechanical problem: See the proper fluid
pump manual for the sprayer for further trou-
NO
ble shooting procedures.
Replace the control board.
NO
187