Connection

These hobs must be connected to the mains using a socket in compliance with publication CEI
60083 or an all-pole circuit-breaker device in compliance with the installation rules in force.
When power is first supplied to your hob, or after an extended power cut, an indicator light will
appear on the control panel. This information will disappear after 30 seconds.
• 220-240V
~
Blue
Brown
N
32A
Neutral
• 2x230V 2L+2N
~
Separate the wires before connection.
Brown
Blue
N1
N2
Neutral
• 400V 3
- 16A
~
Black or grey
Green/yellow
L
Phase
Earth
- 16A
Black-grey
Green/yellow
L1 L2
Phase
Earth
Blue
Brown
Neutral Phase
16A
• 400V 2N
- 16A
~
Separate the 2 phase wires (L1 and L2) before
connection.
Brown
Blue
N
Neutral
With hook-up of 400 V 2N three phase, verify
that the neutral wire is properly connected.
Warning
If the cable is damaged it must be
replaced by the manufacturer, its after-
sales service or a person with a similar
qualification to prevent danger.