Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
1 1 / INSTALLING YOUR APPLIANCE

Connection

This hob must be connected to the mains via an accessible socket complying with publication
IEC 60083 or an all-pole circuit-breaker device complying with current installation rules.
When power is first supplied to your hob, or after an extended power cut, a code will be
displayed on the control panel. This information will disappear after 30 seconds.
• 220-240 V single phase
1 1 6 6 and 3 3 2 2 Amp fuses
Brown
Blue
Green/yellow
Green/yellow
Blue
Brown
Black-grey
• 400V 3N three phase
Separate the 2 phase wires (L2 and L3) before
connection.
1 1 6 6
Brown
Blue
Green/yellow
Green/yellow
Blue
Brown
Black-grey
For a 400 V 3N three-phase connection, in the
event of problems using your hob, make sure
that the neutral conductor is properly
connected.
L L
L L i i v v e e
1 1 6 6 A A
N N
N N e e u u t t r r a a l l
E E a a r r t t h h
E E a a r r t t h h
N N
N N e e u u t t r r a a l l
3 3 2 2 A A
L L
L L i i v v e e
Amp. fuse.
L L 1 1
L L i i v v e e
N N
N N e e u u t t r r a a l l
E E a a r r t t h h
L L 2 2
L L i i v v e e
L L 3 3
L L i i v v e e
Brown
Blue
Green/yellow
Green/yellow
Blue
Brown
Black-grey
Warning
If the cable is damaged, it must be
replaced by the manufacturer, its after-
sales department or a similarly qualified
person .
5
6 6 3 3 Amp fuse.
L L i i v v e e
N N e e u u t t r r a a l l
E E a a r r t t h h
EN
L L
N N

Publicité

Table des Matières
loading

Table des Matières