Checking Burner Cap Placement
Check to make sure that there is no gap between the
burner parts. You may gently try to move the burner parts
from side to side to check if they are properly placed.

Check the Installation

Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some yellow streaking is normal during the initial start-
up. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.

Removing the appliance

Disconnect the appliance from the power and the gas
supply. Push out the appliance from below.
9
CAUTION
Risk of damage! Do not lever out the appliance
from above.